Elevator doors shall open and close automatically....
Search Results "Clear Opening"
Commonly Searched Documents
-
4.10.6* Door Protective and Reopening Device
-
4.10.6* DOOR PROTECTIVE AND REOPENING DEVICE
Elevator doors shall open and close automatically....
-
Toilet Buildings and Pit Toilets
If these clear space requirements can't be met due to a condition for an exemption, then the clear space must meet the technical requirements to the extent practicable....
-
Operable Parts: ADA Standard Section 707.3
Unless a clear or correct key is provided, each operable part shall be able to be differentiated by sound or touch, without activation. , EXCEPTION: Drive-up only automatic teller machines...
-
408.3.2.2 Duration
Power-operated swinging doors shall remain open for 20 seconds minimum when activated....
-
408.3.2 Swinging Doors
Swinging hoistway doors shall open and close automatically and shall comply with 404, 407.3.2 and 408.3.2....
-
11B-408.3.2.2 Duration
Power-operated swinging doors shall remain open for 20 seconds minimum when activated....
-
407.3.5 Door Delay
Elevator doors shall remain fully open in response to a car call for 3 seconds minimum....
-
408.3.2 Swinging Doors
Swinging hoistway doors shall open and close automatically and shall comply with 404, 407.3.2 and 408.3.2....
-
408.3.2.2 Duration
Power-operated swinging doors shall remain open for 20 seconds minimum when activated....
-
407.3.5 Door Delay
Elevator doors shall remain fully open in response to a car call for 3 seconds minimum....
-
11B-408.3.2.2 Duration
Power-operated swinging doors shall remain open for 20 seconds minimum when activated....
-
11B-408.3.2.2 Duration
Power-operated swinging doors shall remain open for 20 seconds minimum when activated....
- Salsbury Industries Recessed Mounted Cell Phone Storage Locker 7 Door High Unit Master Keyed Locks
- Salsbury Industries Recessed Mounted Cell Phone Storage Locker 5 Door High Unit
- Salsbury Industries Recessed Mounted Cell Phone Storage Locker 7 Door High Unit Resettable Combination Locks
- Salsbury Industries Recessed Mounted Cell Phone Storage Locker 7 Door High Unit
-
1013.2 Where required
Guards shall be located along open-sided walking surfaces, including mezzanines, equipment platforms, stairs, ramps and landings that are located more than 30 inches (762 mm) measured vertically...
-
1015.2 Where required
Guards shall be located along open-sided walking surfaces, including mezzanines, equipment platforms, aisles, stairs, ramps and landings that are located more than 30 inches (762 mm) measured...
-
Entry Points and Seats: ADA Standard Section 1008.4.4
Where play components require transfer to entry points or seats, the entry points or seats shall be 11 inches (280 mm) minimum and 24 inches (610 mm) maximum from the clear floor or ground...
-
Escalators: ADA Standard Section 810.9
Where provided, escalators shall comply with the sections 6.1.3.5.6 and 6.1.3.6.5 of ASME A17.1 (incorporated by reference, see “Referenced Standards” in Chapter 1) and shall have a clear...
-
4.10.8 Door Delay for Car Calls
The minimum time for elevator doors to remain fully open in response to a car call shall be 3 seconds....
-
4.10.8 DOOR DELAY FOR CAR CALLS
The minimum time for elevator doors to remain fully open in response to a car call shall be 3 seconds....
-
Turning Space: ADA Standard Section 809.2.2
For example, in kitchens, 804.3.1 requires at least one work surface with clear floor space complying with 306 to be centered beneath....