Section 1006.3.2 of the 2010 Standards requires that where curbs or other constructed barriers prevent golf cars from entering a fairway, openings 60 inches wide minimum shall be provided...
Search Results "Parallel Curb Ramp"
-
Accessible Teeing Grounds, Putting Greens, and Weather Shelters
-
903 Benches
The proposed rule specified that the wheelchair space be positioned so that it provides a parallel approach to an end of the bench seat (903.2)....
-
Handrail Extensions
If handrail extensions are provided, they do not need to be parallel with the ground or floor surface, since the surface may be moving due to water conditions....
-
NPRM and Comments
Transit industry commenters suggested that no changes were needed from existing regulations and that there was not a problem that the Department need remedy if parallel accessible transit...
-
Other Definitions
The Department will consider whether, in the future, to propose changes to part 37 to parallel the new DOJ definitions. Meanwhile, the existing DOT definitions continue in effect....
-
§ 38.125(b)(2)(ii) Exception
deployment at some stops of a lift having its long dimension perpendicular to the car axis, the transportation entity may specify a lift which is designed to deploy with its long dimension parallel...
-
§ 38.83(b)(2)(ii) Exception
deployment at some stops of a lift having its long dimension perpendicular to the vehicle axis, the transportation entity may specify a lift which is designed to deploy with its long dimension parallel...
-
§ 38.95(b)(2)(ii) Exception
deployment at some stops of a lift having its long dimension perpendicular to the car axis, the transportation entity may specify a lift which is designed to deploy with its long dimension parallel...
-
R409.10 Handrail Extensions
Handrail gripping surfaces shall extend beyond and in the same direction of ramp runs and stair flights in accordance with R409.10....
-
§ 38.25(c) Door height
For vehicles in excess of 22 feet in length, the overhead clearance between the top of the door opening and the raised lift platform, or highest point of a ramp, shall be a minimum of 68...
-
R305.2 Placement
Where the back of curb edge is tooled to provide a radius, the border dimension should be measured from the end of the radius....
-
Edge Protection
ADAAG addresses drop-offs along ramps and ramp landings but not along other portions of accessible routes or circulation paths....
-
1127B.1
be designed to provide access to all entrances and exterior ground floor exits, and access to normal paths of travel, and where necessary to provide access, shall incorporate pedestrian ramps...
-
Reasonable Modification of Policies and Procedures
If a city requires a 12-foot set-back from the curb in the central business district, it may be reasonable to grant a 3-foot variance for a store wishing to install a ramp at its entrance...
-
CIRCULATION PATH
[DSA-AC] An exterior or interior way of passage provided for pedestrian travel, including but not limited to, walks, sidewalks, hallways, courtyards, elevators, platform lifts, ramps, stairways...
-
CIRCULATION PATH
[DSA-AC] An exterior or interior way of passage provided for pedestrian travel, including but not limited to, walks, sidewalks, hallways, courtyards, elevators, platform lifts, ramps, stairways...
-
11B-405.9.1 Reserved
The floor or ground surface of the ramp run or landing shall extend 12 inches (305 mm) minimum beyond the inside face of a handrail complying with 505....
-
A. Accessible Voting Program
condition on Election Day those features of facilities and equipment (including, but not limited to, permanent equipment such as lifts and elevators, and temporary equipment such as portable ramps...
- Yale 1100 Series Industrial Door Closer
- Yale 2700 Series Architectural Door Closer
- Palmer Fixture BluStorm® Bolt High Speed Hand Dryer HD0923
-
11B-405.9.1 Reserved
The floor or ground surface of the ramp run or landing shall extend 12 inches (305 mm) minimum beyond the inside face of a handrail complying with 505....
-
Original research for ANSI A117.1 (1957 - 1961)
In the original research for ANSI A117.1 - 1961, American National Standard Specifications for Making Buildings and Facilities Accessible to, and Usable by, the Physically Handicapped, ramps...
-
11B-405.9.1 Reserved.
The floor or ground surface of the ramp run or landing shall extend 12 inches (305 mm) minimum beyond the inside face of a handrail complying with 505....