Other key factors that guide MDE manufacturers in their equipment design include: the nature of the specific diagnostic objective; safety requirements; FDA regulations (specifically 21CFR...
Search Results "Diagnostic Room"
-
2.4.2 Considerations of Manufacturers in Accessible MDE Design
-
M301.2.3 Size (Section-by-Section Analysis)
The MDE NPRM proposed a transfer surface size for diagnostic equipment used in the supine, prone, or side-lying position of 30 inches wide and 15 inches deep minimum....
-
M302.2.1 Adjustability (Section-by-Section Analysis)
The MDE NPRM proposed a transfer surface height range for diagnostic equipment used by patients in a seated position of 17 inches minimum and 19 inches maximum....
-
L. Eligibility of National Origin Minority Persons With Limited English Language Skills
(1) Identification by administrative staff, teachers, or parents of secondary level students; (2) identification by the student in postsecondary or adult programs; and (3) appropriate diagnostic...
-
13.3 Alteration
13.3 “Alteration” solely for purposes of this Consent Decree, shall mean and refer to an alteration to an accessible guest room or guest room toilet room that (1) increases or decreases...
-
M305.3 Standing Supports (Section-by-Section Analysis)
M305.3 provides the technical requirements for standing supports which are required on diagnostic equipment covered by M304....
-
5.4.3 Transfer Support Height for M301 and M302
NPRM Preamble Discussion: The Access Board is considering whether 6 inches minimum and 19 inches maximum above the transfer surface would be an appropriate height for transfer supports on diagnostic...
-
5.1.1 Transfer Surface Height Adjustability Recommendation for M301 and M302
The adjustability of medical diagnostic equipment will facilitate transfers for all types of patient populations by providing the ability to “pair” the transfer surface of diagnostic equipment...
-
11B-201.2 Application based on building or facility use
Where a site, building, facility, room, or space contains more than one use, each portion shall comply with the applicable requirements for that use....
-
11B-201.2 Application based on building or facility use
Where a site, building, facility, room, or space contains more than one use, each portion shall comply with the applicable requirements for that use....
-
25. RESERVATIONS SYSTEM
) until those rooms are the last non-premium rooms available....
-
11B-813.2.12 Signs
A room identification sign complying with Section 11B-216 shall be provided at entrances to adult changing facilities....
-
11B-813.2.12 Signs
A room identification sign complying with Section 11B-216 shall be provided at entrances to adult changing facilities....
- VE EXPLORER Touchscreen Vending Machine
-
11B-219.5 Permanent and portable systems
If portable assistive-listening systems are used for conference or meeting rooms, the system may serve more than one room....
-
11B-219.5 Permanent and portable systems
If portable assistive-listening systems are used for conference or meeting rooms, the system may serve more than one room....
-
M301.2.1 Adjustability (Section-by-Section Analysis)
The MDE NPRM proposed a transfer surface height range for diagnostic equipment used by patients in the supine, prone, or side-lying position of 17 inches minimum and 19 inches maximum....
-
Medical Kiosks
Medical Kiosks Healthcare kiosks include, but are not limited to, self check-in kiosks, physician videoconferencing systems, diagnostic kiosks, health/medication information dispensaries...
-
M302.2.3 Size (Section-by-Section Analysis)
The MDE NPRM proposed a transfer surface size for diagnostic equipment used by patients in the seated position of 21 inches wide and 15 inches deep (proposed M302.2.2)....
-
1. Transfer Supports
The requirements were the same for transfer surfaces on diagnostic equipment used by patients in the supine, prone, or side-lying position, as well as diagnostic equipment used by patients...
-
5.4.6 Transfer Support Gripping Surface Cross Section and Clearances for M301, M302, and M305.2
The Access Board is considering whether the above cross section dimensions would be appropriate for the gripping surfaces of transfer supports on diagnostic equipment used by patients in...
-
Information about Autism Spectrum Disorder (ASD)
According to the most recent Diagnostic and Statistical Manual of Mental Disorder (DSM-5), ASD is a neurodevelopmental disorder that is characterized by persistent deficits in social communication...
-
[F] 907.5.2.3.1 Public and common use areas
notification appliances shall be provided in public use areas and common use areas, including but not limited to: Sanitary facilities including restrooms, bathrooms and shower rooms...
-
11B-804.2.3 Turning space
In kitchens within multi-bedroom housing units and on floors containing accessible sleeping rooms with adaptable features in undergraduate student housing, turning spaces complying with...