Where the clear width of an ORAR is less than 60 inches, passing spaces must be provided at intervals of at least 200 feet....
Search Results "Clear"
-
Passing Spaces [1016.4]
-
Circulation Paths
Objects that overhang circulation paths do not provide clear headroom....
- Aqua Creek Scout Excel
- Door Scope® Door Viewer
- Landscape Forms Inc. Palisade Bench Collection
- Mighty 400 Pool & Spa Access Lift
-
Comparison of Single-User Toilet Room Layouts: 2A, 2B, and 2C
The in-swinging door increases overall room size because it cannot swing over the required clear floor space at any accessible fixture, (see section 4.22.2 of the 1991 Standards)....
-
§382.9(d)
provision of this part, and that the carrier has provided an effective alternative means of achieving the objective of the provisions of this part subject to the waiver or have demonstrated by clear...
-
11B-1003.3 Clearances
Although the minimum width of the clear pier space is 60 inches (1525 mm), it is recommended that piers be wider than 60 inches (1525 mm) to improve the safety for persons with disabilities...
-
11B-902.4 Dining surfaces and work surfaces for children’s use
Exception: Dining surfaces and work surfaces that are used primarily by children 5 years and younger shall not be required to comply with Section 11B-902.4 where a clear floor or ground...
-
404.3.6 Break Out Opening
Where doors and gates without standby power are a part of a means of egress, the clear break out opening at swinging or sliding doors and gates shall be 32 inches (815 mm) minimum when operated...
-
Define "task." (Section-by-Section Analysis)
The Department feels that the common definition of task is sufficiently clear and that it is not necessary to add to the definitions section. ...
-
4.2.6* Side Reach
If the clear floor space allows parallel approach by a person in a wheelchair, the maximum high side reach allowed shall be 54 in (1370 mm) and the low side reach shall be no less than 9...
-
A4. Vertical Clearance
[ADA Stds 4.6.5] If No: Can the route be cleared by removing or raising low objects or can each van accessible parking space be relocated? Yes _____ No _____...
-
4.2.5 FORWARD REACH
If the clear floor space only allows forward approach to an object, the maximum high forward reach allowed shall be 48 in (1220 mm) (see Fig. 5(a))....
-
2.5.3 Width
Where resting intervals are provided adjacent to an outdoor recreation access route, the resting interval clear width shall be 36 inches (915 mm) minimum. ...
-
A4.34.6.7 OVENS
Clear spaces at least 30 in (760 mm) wide under counters at the side of ovens are an added convenience....
-
Islands [§406.7]
Islands [§406.7] A 48” min. long separation is necessary between curb ramps so that people using wheelchairs can clear one ramp before negotiating the next....
-
11B-1003.3 Clearances
Although the minimum width of the clear pier space is 60 inches (1525 mm), it is recommended that piers be wider than 60 inches (1525 mm) to improve the safety for persons with disabilities...
-
11B-902.4 Dining surfaces and work surfaces for children’s use
Exception: Dining surfaces and work surfaces that are used primarily by children 5 years and younger shall not be required to comply with Section 11B-902.4 where a clear floor or ground...
-
11B-1003.3 Clearances
Although the minimum width of the clear pier space is 60 inches (1525 mm), it is recommended that piers be wider than 60 inches (1525 mm) to improve the safety for persons with disabilities...
-
11B-902.4 Dining surfaces and work surfaces for children’s use
Exception: Dining surfaces and work surfaces that are used primarily by children 5 years and younger shall not be required to comply with Section 11B-902.4 where a clear floor or ground...
-
404.3.6 Break Out Opening
Where doors and gates without standby power are a part of a means of egress, the clear break out opening at swinging or sliding doors and gates shall be 32 inches (815 mm) minimum when operated...
-
902.4 Dining Surfaces and Work Surfaces for Children's Use
EXCEPTION: Dining surfaces and work surfaces that are used primarily by children 5 years and younger shall not be required to comply with 902.4 where a clear floor or ground space complying...