Grab bars shall be installed in a horizontal position, 33 inches (840 mm) minimum and 36 inches (915 mm) maximum above the finish floor measured to the top of the gripping surface, except...
Search Results "Ceramic Tile Flooring"
Commonly Searched Documents
-
609.4 Position of Grab Bars
-
4.10.13* CAR POSITION INDICATORS
As the car passes or stops at a floor served by the elevators, the corresponding numerals shall illuminate, and an audible signal shall sound....
-
11B-405.9.2 Curb or barrier
mm) high minimum, or barrier shall be provided that prevents the passage of a 4 inch (102 mm) diameter sphere, where any portion of the sphere is within 4 inches (102 mm) of the finish floor...
-
§ 38.23(b)(7) Platform gaps
When the platform is at vehicle floor height with the inner barrier (if applicable) down or retracted, gaps between the forward lift platform edge and the vehicle floor shall not exceed...
-
11B-405.9.2 Curb or barrier
A curb or barrier shall be provided that prevents the passage of a 4-inch (102 mm) diameter sphere, where any portion of the sphere is within 4 inches (102 mm) of the finish floor or ground...
-
[A] ADDITION
[DSA-AC] An expansion, extension, or increase in the gross floor area or height of a building or facility....
-
11B-411.4.8.2.1 Signal type
The signal shall be an automatic verbal annunciator which announces the floor at which the car is about to stop....
-
602.4 Spout Height
Spout outlets shall be 36 inches (915 mm) maximum above the finish floor or ground....
-
602.4 Spout Height
Spout outlets shall be 36 inches (915 mm) maximum above the finish floor or ground....
-
11B-602.4 Spout height
Spout outlets shall be 36 inches (914 mm) maximum above the finish floor or ground....
-
4.24.2 HEIGHT
Sinks shall be mounted with the counter or rim no higher than 34 in (865 mm) from the floor....
-
11B-411.4.8.2.1 Signal type
The signal shall be an automatic verbal annunciator which announces the floor at which the car is about to stop....
-
11B-602.4 Spout height
Spout outlets shall be 36 inches (914 mm) maximum above the finish floor or ground....
-
11B-411.4.8.2.1 Signal type
The signal shall be an automatic verbal annunciator which announces the floor at which the car is about to stop....
-
11B-813.2.1 Adult changing table
Adult changing tables shall be fixed to the floor or a wall and shall comply with Section 11B-813.2.1....
-
Telescopes and Periscopes
Whenever a telescope or periscope is provided, ensure that a separate telescope or periscope is available for use from a standing position (60 inches above the floor or ground surface is...
-
1134A.8 Lavatories, vanities, mirrors and towel fixtures
The top of the fixture rim shall be a maximum of 34 inches (864 mm) above the finished floor. 2. Floor space....
-
404.2.3 Clear Width
There shall be no projections into the required clear opening width lower than 34 inches (865 mm) above the finish floor or ground....
-
11B-404.2.3 Clear width
There shall be no projections into the required clear opening width lower than 34 inches (864 mm) above the finish floor or ground....
-
Shower Threshold
Board has provided an exception for existing facilities to address situations where meeting the maximum threshold height, which is typically achieved by recessing shower pans into the floor...
-
404.2.3 Clear Width
There shall be no projections into the required clear opening width lower than 34 inches (865 mm) above the finish floor or ground....
-
1134A.7, Item 2
Where the water closet is not placed adjacent to a side wall capable of accommodating a grab bar, the bathroom shall have provisions for installation of floor-mounted, foldaway or similar...
-
211 Drinking Fountains
Design 2010 Standards for Accessible Design What’s New/Different 4.1.3(10)(a) Where only one drinking fountain is provided on a floor...
-
Drinking Fountains
Requirement: 4.1.3(10)* Drinking Fountains: (a) Where only one drinking fountain is provided on a floor there shall be a drinking fountain which is accessible to individuals who use...