In assembly areas, aisle stairs shall not be required to comply with Section 11B-504 except that striping complying with Section 11B-504.4.1 shall be provided. [2010 ADAS] 3....
Search Results "Aisle Ramp"
-
11B-210.1 General
-
11B-210.1 General
In assembly areas, aisle stairs shall not be required to comply with Section 11B-504 except that striping complying with Section 11B-504.4.1 shall be provided....
-
1009.2.1 Elevators required
buildings equipped throughout with an automatic sprinkler system installed in accordance with Section 903.3.1.1 or 903.3.1.2, the elevator shall not be required on floors provided with a ramp...
-
11B-108 Maintenance of accessible features
It is not sufficient to provide features such as accessible routes, parking, elevators, ramps or signage if those features are not maintained in a manner that enables individuals with disabilities...
- Harmar CPL400P Portable Vertical Platform Lift
-
303.3 Beveled
Changes in level exceeding ½ inch (13 mm) must comply with 405 (Ramps) or 406 (Curb Ramps). Figure 303.3 Beveled Change in Level ...
-
Comments from Individuals Who Are Blind or Have Low Vision (Section-by-Section Analysis)
Blind was a member of the advisory committee that recommended the proposed guidelines, but filed a minority report recommending detectable warning surfaces should be required only on curb ramps...
-
R302.6 Cross Slope
Cross slope requirements are contained in R304.5.3 for curb ramps and blended transitions, and in R407.3 for ramps....
-
Slope [4.3.7]
Where the running slope of an accessible route exceeds 5% it must be treated as a ramp or curb ramp. A maximum cross slope of 2% is recognized for drainage....
-
11B-405.9.2 Curb or barrier
To prevent wheel entrapment, the curb or barrier shall provide a continuous and uninterrupted barrier along the length of the ramp....
-
907.5.2.3 Visible alarms
Visible alarm notification appliances shall not be required in enclosed exit stairways, enclosed exit ramps, exterior exit stairs and exterior exit ramps. 3....
-
[F] 907.5.2.3 Visible alarms
Visible alarm notification appliances shall not be required in enclosed exit stairways, enclosed exit ramps, exterior exit stairs and exterior exit ramps....
-
11B-405.9.2 Curb or barrier
To prevent wheel entrapment, the curb or barrier shall provide a continuous and uninterrupted barrier along the length of the ramp....
-
R305 Detectable Warning Surfaces (Section-by-Section Analysis)
At curb ramps and blended transitions, detectable warning surfaces must extend the full width of the ramp run (excluding flared sides), blended transition, or turning space....
-
1. Typical Issues for Individuals Who Use Wheelchairs, Scooters, or Other Mobility Devices
Where ramps are used, they cannot be steeper than 1:12. Ramps with a vertical rise of more than 6 inches must have handrails on both sides....
-
Part 1. Typical Issues for Voters Who Use Wheelchairs, Scooters, or Other Mobility Devices
Where ramps are used, they cannot be steeper than 1:12. Ramps with a vertical rise of more than 6 inches must have handrails on both sides....
-
11B-226.1 General
Check writing surfaces provided at check-out aisles not required to comply with Section 11B-904.3 shall not be required to comply with Section 11B-902....
-
B8. Accessible Route
Does an accessible route connect the curb ramp to the accessible entrance? [ADA Stds 4.1.2(1)]...
-
Suggestion by Eldon Tipping
Eldon Tipping As published in Concrete Construction magazine, September 1998, Eldon Tipping made suggestions for a specification for sloped random - traffic floors such as parking decks, ramps...
-
Architectural Barriers
narrow to accommodate people who use wheelchairs; a step or steps at the entrance or to part of the selling space of a store; round doorknobs or door hardware that is difficult to grasp; aisles...
-
11B-504.4.1 Contrasting stripe
It should be noted that CBC Chapter 10 has a different requirement for contrasting stripes at stepped aisles in Assembly occupancies (not adopted by DSA-AC, as this is a life safety requirement...
-
4. Grievance Procedure
Curb ramp requests submitted through the City's grievance procedure trigger an investigation by DPW....
-
11B-303.3 Beveled
Changes in level exceeding ½ inch (13 mm) must comply with 405 (Ramps) or 406 (Curb Ramps). FIGURE 11B-303.3 BEVELED CHANGE IN LEVEL...
-
T503.5 Exterior Illumination for Boarding and Alighting Areas
Where doorways have ramps, bridgeplates or lifts, the illumination shall be 1 foot-candle (11 lux) minimum for a distance of 3 feet (915 mm) measured beyond the edge of the ramp, bridgeplate...