Single-User Toilet Rooms: Split Plumbing Water closets and lavatories can be located on opposing walls....
Search Results "Viewing Location"
-
Single-User Toilet Rooms: Split Plumbing
-
11B-603.3 Mirrors
Mirrors located above lavatories or countertops shall be installed with the bottom edge of the reflecting surface 40 inches (1016 mm) maximum above the finish floor or ground....
-
Curb Ramps
Error/Omission: Curb ramp that is located across a circulation path has steep unprotected side flares. Result: People walking across the curb ramp may trip and be injured....
-
11B-408.1 General
Accessibility scoping requirements for elevators and lifts are located in Sections 11B-206.6 and 11B-207.6 [sic]; technical requirements are located in Sections 11B-407, 11B-408, 11B-409...
-
Commercial Facilities in Private Residences (Preamble, Section-by-Section Analysis)
Commercial Facilities in Private Residences Section 36.401(b) of the final rule is a new provision relating to commercial facilities located in private residences....
-
1117B.5.7
California's standards for signage are more stringent than Section 4.30 of the ADA Standards for Accessible Design. 1117B.5.7 Mounting location and height. ...
-
Commercial Facilities in Private Residences (Section-By-Section Analysis and Response to Comments)
Commercial Facilities in Private Residences (Section-By-Section Analysis and Response to Comments) Section 36.401(b) of the final rule is a new provision relating to commercial facilities located...
- Easterseals of Mahoning, Trumbull and Columbiana Counties
-
11B-604.8.1.2 Doors
Doors shall be located in the front partition or in the side wall or partition farthest from the water closet....
-
11B-1008.3 Transfer systems
Designers should minimize the distance between the points where a child transfers from a wheelchair or mobility device and where the elevated play components are located....
-
11B-603.6 Guest room toilet and bathing rooms
Toilet and bathing rooms within guest rooms that are not required to provide mobility features complying with Section 11B-806.2 shall provide all toilet and bathing fixtures in a location...
-
11B-703.7.2.6.3 Unisex toilet and bathing facilities
The vertices of the triangle shall be located ¼ inch (6.4 mm) maximum from the edge of the circle....
-
11B-1008.3 Transfer systems
Designers should minimize the distance between the points where a child transfers from a wheelchair or mobility device and where the elevated play components are located....
-
11B-703.7.2.6.3 Unisex toilet and bathing facilities
The vertices of the triangle shall be located ¼ inch (6.4 mm) maximum from the edge of the circle....
-
§382.57(c)(7)(i) Visibility
The display screen must be visible from a point located 40 inches (1015 mm) above the center of the clear floor space in front of the automated kiosk....
-
11B-608.10 Soap dish
Where a soap dish is provided, it shall be located on the control wall at 40 inches (1016 mm) maximum above the shower floor, and within the reach limits from the seat....
-
Sec.36.603(b)(1)
(1) Adequate public notice of intention to file a request for certification, notice of a hearing, and notice of the location at which the request and materials can be inspected is published...
-
305.7 Maneuvering Clearance
Where a clear floor or ground space is located in an alcove or otherwise confined on all or part of three sides, additional maneuvering clearance shall be provided in accordance with 305.7.1...
-
Question 6
If the accessible route is not the main route to the business, are the directional signs to the accessible route still readable and located at the main entrance and key points along the...
-
Toilets
Provide a toilet seat that is 17" to 19" above the finished floor in the north women's toilet room located in the "Celebrity Spies" exhibit area. See Standards § 4.16.3....
-
305.7 Maneuvering Clearance
Where a clear floor or ground space is located in an alcove or otherwise confined on all or part of three sides, additional maneuvering clearance shall be provided in accordance with 305.7.1...
-
5.2.1.3 Transfer Surface Size for Stretchers
The transfer surface should be 28 inches wide minimum and 17 inches deep minimum located on both long sides of stretchers....
-
R212.4 Tables
At least 5 percent, but no less than one, of tables at each location shall comply with section 902 of Appendix D to 36 CFR part 1191....
-
5.4.5 Transfer Support Position for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
The transfer gripping surface should be located within the minimum and maximum heights....