For many patients who use mobility devices, independent transfer is possible only if the height of the transfer surface is at or near the seat height of their mobility device....
Search Results "Designated Aisle Seat (Assembly)"
-
Transfer Surface Height (M301.2.1 and M302.2.1)
-
M303.2.4 Equipment Clearances (Section-by-Section Analysis)
The MDE NPRM proposed knee and toe clearance for diagnostic equipment used by patients seated in wheelchairs to allow for components in the wheelchair space which the patient could approach...
- Sloan WETS 2050.1401-1.28 G2 OPTIMA Plus Systems Activated HET Flushometer and HET Wall Hung Water Closet
- U. S. Department of Veterans Affairs Office of Construction & Facilities Management Technical Information Library (TIL)
-
T213.2 Priority Seats
Non-rail vehicles operated in fixed-route service shall designate at least two seats as priority seats for passengers with disabilities....
-
§382.41 What flight-related information must carriers provide to qualified individuals with a disability?
As a carrier, you must provide the following information, on request, to qualified individuals with a disability or persons making inquiries on their behalf concerning the...
-
204.1 General
204.1 General. Protruding objects on circulation paths shall comply with 307. EXCEPTIONS: 1. Within areas of sport activity, protruding objects on circulation paths shall not be...
-
204.1 General
Protruding objects on circulation paths shall comply with 307. EXCEPTIONS: 1. Within areas of sport activity, protruding objects on circulation paths shall not be required to...
-
M303.2 Wheelchair Spaces
Wheelchair spaces complying with M303.2 shall be provided at diagnostic equipment.
-
M303.2.3 Depth
The depth of wheelchair spaces shall comply with M303.2.3.
-
M302.3.3 Head and Back Support
Where the diagnostic equipment is used in a reclined position, head and back support shall be provided and shall comply with M305.5.
-
M302.2.4 Transfer Sides
Options to transfer from a mobility device shall be provided on two adjoining sides of transfer surfaces. EXCEPTION: Options to transfer to or from a mobility device onto...
-
M303.2 Wheelchair spaces (Section-by-Section Analysis)
This is an introductory section.
-
EXHIBIT B
EXHIBIT B The average anthropometric dimensions employed shall be: (1) average eye height for a person sitting in a wheelchair is 47.45"; (2) horizontal distance from the eye of...
-
5.2.3 Transfer Surface Measurement
5.2.3 Transfer Surface Measurement. The transfer surface should be measured from the center-point of each side of the transfer surface.
-
5.3.3.1 Transfer Sides for Exam Chairs with Fixed Footrests
5.3.3.1 Transfer Sides for Exam Chairs with Fixed Footrests. The 17 inch minimum depth and 21 inch minimum width should be located on both sides of examination chairs with a fixed...
-
CHAPTER 9: BUILT-IN ELEMENTS
CHAPTER 9: BUILT-IN ELEMENTS
-
M302.2.3 Transfer Sides
The transfer surface shall be located to provide options to transfer from a mobility device onto one short side (depth) and one long side (width) of the surface. Each transfer side...
-
M303.2.3 Depth
Where wheelchair spaces can be entered from the front or rear, the wheelchair space shall be 48 inches (1220 mm) deep minimum. Where wheelchair spaces can be entered only from the...
-
M302.3.3 Head and Back Support
Where the diagnostic equipment is used in a reclined position, head and back support shall be provided. Where the incline of the back support can be modified while in use, head and...
-
M303.2.2 Width
Wheelchair spaces shall be 36 inches (915 mm) wide minimum.
-
DSA Drawing 11B-406-5C Curb Ramp Adjoining a Parking Access Aisle next to a Curb and Gutter (2016 CBC)
Requires the Premium User plan or above. (Login or upgrade your account!)
-
DSA Drawing 11B-406-1C Curb Ramp Adjoining a Parking Access Aisle next to a Curb and Gutter (2016 CBC)
Requires the Premium User plan or above. (Login or upgrade your account!)