Detectable warnings shall be provided where required by Section 11B-247.1.2....
Search Results "Warning Signal"
Commonly Searched Documents
- 
    
  
  11B-247.1.2 Where required
  
 - 
    
  
  11B-705.1.2 Locations
  
Detectable warnings at the following locations shall comply with Section 11B-705.1....
 - 
    
  
  705.1 General
  
Detectable warnings shall consist of a surface of truncated domes and shall comply with 705....
 - 
    
  
  11B-705.1.1.3.1
  
Detectable warning surfaces shall be yellow and approximate FS 33538 of Federal Standard 595C....
 - 
    
  
  11B-705.1.1.3.1
  
Detectable warning surfaces shall be yellow and approximate 33538 of SAE AMS-STD-595A....
 - 
    
  
  Comments from Individuals Who Are Blind or Have Low Vision (Section-by-Section Analysis)
  
Section-by-Section Analysis) The National Federation of the Blind was a member of the advisory committee that recommended the proposed guidelines, but filed a minority report recommending detectable warning...
 - 
    
  
  11B-705.1.1 General
  
Detectable warnings shall consist of a surface of truncated domes and shall comply with Section 11B-705....
 - 
    
  
  705.1 General
  
Detectable warnings shall consist of a surface of truncated domes and shall comply with 705....
 - 
    
  
  11B-705.1.2 Locations
  
Detectable warnings at the following locations shall comply with Section 11B-705.1....
 - 
    
  
  11B-705.1.1 General
  
Detectable warnings shall consist of a surface of truncated domes and shall comply with Section 11B-705....
 - 
    
  
  4.29.7* STANDARDIZATION
  
Textured surfaces for tactile door warnings shall be standard within a building, facility, site, or complex of buildings....
 - 
    
  
  11B-705.1.1.3.1
  
11B-705.1.1.3.1 Detectable warning surfaces shall be yellow and approximate FS 33538 of Federal Standard 595C....
 - 
    
  
  11B-705.1.1 General
  
Detectable warnings shall consist of a surface of truncated domes and shall comply with Section 11B-705....
 - 
    
  
  705.1 General
  
Detectable warnings shall consist of a surface of truncated domes and shall comply with 705. Figure 705.1 Size and Spacing of Truncated Domes...
 - 
    
  
  Door and Signal Timing for Hall Calls [4.10.7], Door Delay for Car Calls [4.10.8]
  
Timing, based on the distance between the farthest call button and the elevator door, begins with visible and audible signaling of car arrival....
 - 
    
  
  R305.1 General
  
Detectable warning surfaces shall consist of truncated domes aligned in a square or radial grid pattern and shall comply with R305....
 - Detectable Warning Systems, Inc. AlertCast® Cast-in-Place Detectable Warning installation Video
 - 
    
  
  Doors to Hazardous Areas (Reserved) [4.29.3] and Stairs (Reserved) [4.29.4]
  
Doors to Hazardous Areas (Reserved) [4.29.3] and Stairs (Reserved) [4.29.4] In the absence of a clear consensus on the need or specification for detectable warnings at doors and stairs...
 - 
    
  
  4.10.4(1)
  
(1) Hall lantern fixtures shall be mounted so that their centerline is at least 72 in (1830 mm) above the lobby floor. (See Fig. 20.)
 - 
    
  
  11B-408.2.2 Hall signals
  
Hall signals shall comply with Section 11B-407.2.2....
 - 
    
  
  11B-408.2.2 Hall signals
  
Hall signals shall comply with Section 11B-407.2.2....
 - 
    
  
  11B-408.2.2 Hall signals
  
Hall signals shall comply with Section 11B-407.2.2....
 - 
    
  
  Issue 12: Audible beaconing
  
Issue 12: Audible beaconing Audible beaconing -- providing a louder audible WALK signal in order to provide directional guidance to pedestrians who are blind -- is not needed at all intersections...
 - 
    
  
  3.3 Guidance on the Visual Properties of Detectable Warnings
  
On dark sidewalks (e.g. asphalt) use light colored detectable warnings with a high reflectance fact or to provide light-on-dark contrast rather than using darker detectable warnings to provide...
 
              