Grab bars shall not rotate within their fittings....
Search Results "Vertical Grab Bar"
Commonly Searched Documents
-
609.6 Fittings
-
11B-609.6 Fittings
Grab bars shall not rotate within their fittings....
-
11B-604.8.2.3 Grab bars
Grab bars shall comply with Section 11B-609. A side-wall grab bar complying with Section 11B-604.5.1 shall be provided on both sides of the compartment....
-
609.6 Fittings
Grab bars shall not rotate within their fittings....
-
11B-609.6 Fittings
Grab bars shall not rotate within their fittings....
-
11B-604.8.2.3 Grab bars
Grab bars shall comply with Section 11B-609. A side-wall grab bar complying with Section 11B-604.5.1 shall be provided on both sides of the compartment....
- Bobrick Swing-Up Grab Bar B-4998.99
- Mega Jailhouse Anti-Suicide Grab Bar with Closure Plate 42 inches - Concealed Mounting
-
604.5.1 Side Wall
The side wall grab bar shall be 42 inches (1065 mm) long minimum, located 12 inches (305 mm) maximum from the rear wall and extending 54 inches (1370 mm) minimum from the rear wall....
-
604.5.1 Side Wall
The side wall grab bar shall be 42 inches (1065 mm) long minimum, located 12 inches (305 mm) maximum from the rear wall and extending 54 inches (1370 mm) minimum from the rear wall....
- Mega Jailhouse Anti-Suicide Grab Bar with Closure Plate 24 inches - Concealed Mounting
-
(5) Reinforced walls for grab bars
The final Guidelines for bathroom wall reinforcement remains essentially unchanged from the Option One guidelines. The only change made to these guidelines has been to subject powder...
- Bobrick Swing-Up Grab Bar B-4998
-
11B-607.4.2 Bathtubs without permanent seats
For bathtubs without permanent seats, grab bars shall comply with Section 11B-607.4.2....
-
11B-607.4.1 Bathtubs with permanent seats
For bathtubs with permanent seats, grab bars shall be provided in accordance with Section 11B-607.4.1....
-
607.4.1.1 Back Wall
Two grab bars shall be installed on the back wall, one located in accordance with 609.4 and the other located 8 inches (205 mm) minimum and 10 inches (255 mm) maximum above the rim of the...
-
11B-607.4.1.1 Back wall
Two grab bars shall be installed on the back wall, one located in accordance with Section 11B-609.4 and the other located 8 inches (203 mm) minimum and 10 inches (254 mm) maximum above the...
-
11B-607.4.1.1 Back wall
Two grab bars shall be installed on the back wall, one located in accordance with Section 11B-609.4 and the other located 8 inches (203 mm) minimum and 10 inches (254 mm) maximum above the...
-
11B-604.9.4 Grab bars
Grab bars for water closets shall comply with Section 11B-604.5....
-
11B-604.9.4 Grab bars
Grab bars for water closets shall comply with Section 11B-604.5....
-
607.4.1.1 Back Wall
Two grab bars shall be installed on the back wall, one located in accordance with 609.4 and the other located 8 inches (205 mm) minimum and 10 inches (255 mm) maximum above the rim of the...
-
11B-607.4.1.1 Back wall
Two grab bars shall be installed on the back wall, one located in accordance with Section 11B-609.4 and the other located 8 inches (203 mm) minimum and 10 inches (254 mm) maximum above the...
-
607.4.2.1 Back Wall
Two grab bars shall be installed on the back wall, one located in accordance with 609.4 and other located 8 inches (205 mm) minimum and 10 inches (255 mm) maximum above the rim of the bathtub...
-
607.4.1.1 Back Wall
Two grab bars shall be installed on the back wall, one located in accordance with 609.4 and the other located 8 inches (205 mm) minimum and 10 inches (255 mm) maximum above the rim of the...