5.2.3 Transfer Surface Measurement Recommendation for M301Â and M302 Description: The transfer surface size standard has two components: width and depth....
Search Results "Transfer Surface Height"
Commonly Searched Documents
-
5.2.3 Transfer Surface Measurement Recommendation for M301 and M302
-
1011.4.1 Height
The tops of picnic tables shall comply with 902.3.
-
1011.4.1 Height
The tops of picnic tables shall comply with 902.3.
-
11B-1002.6.2 Transfer height
The height of transfer device seats shall be 14 inches (356 mm) minimum and 24 inches (610 mm) maximum measured from the load and unload surface....
-
11B-1002.6.2 Transfer height
The height of transfer device seats shall be 14 inches (356 mm) minimum and 24 inches (610 mm) maximum measured from the load and unload surface....
-
902.4.2 Height
The tops of tables and counters shall be 26 inches (660 mm) minimum and 30 inches (760 mm) maximum above the finish floor or ground.
-
902.4.2 Height
The tops of tables and counters shall be 26 inches (660 mm) minimum and 30 inches (760 mm) maximum above the finish floor or ground.
-
5.2.1 Transfer Surface Size Recommendations for M301
5.2.1 Transfer Surface Size Recommendations for M301 Description: The transfer surface is the part of the diagnostic equipment onto which patients who use mobility devices or aids transfer...
-
5.3.3.1 Transfer Sides for Exam Chairs with Fixed Footrests
5.3.3.1 Transfer Sides for Exam Chairs with Fixed Footrests....
-
5.2 Transfer Surface Size Recommendations
5.2 Transfer Surface Size Recommendations...
-
M301.3.1 Transfer Supports (Section-by-Section Analysis)
these transfer supports comply with the technical requirements for transfer support in M305.2....
-
5.4.4 Transfer Support Distance from Transfer Surface Recommendations for M301 and M302
surface and can be effectively used to position during a transfer....
-
Transfer Platforms
Transfer Platforms A transfer platform is a platform or landing that an individual who uses a wheelchair or mobility device can use to lift or transfer onto the play structure and leave...
-
Door and Gate Surfaces: ADA Standard Section 404.2.10
Section 404.2.10 covers the current ADA Standards for door and gate surfaces on manual doors and gates.
-
Medical Diagnostic Equipment Accessibility Standards Sub-Committee Recommendations Imaging Equipment
Accessibility Standards for Medical Diagnostic Equipment Medical Diagnostic Equipment Accessibility Standards Sub-Committee Recommendations - Imaging Equipment Final...
- Varidesk LLC. Pro Desk 60â„¢ Height-Adjustable Standing Desk
- Steelcase Ology Series Height-Adjustable Table
-
High work surface
All of the seating spaces/work surfaces were approximately 42" high....
-
5.3.3 Transfer Sides for Equipment Used by Patients in Seated Position
5.3.3 Transfer Sides for Equipment Used by Patients in Seated Position....
-
11B-902.4.2 Height
The tops of tables and counters shall be 26 inches (660 mm) minimum and 30 inches (762 mm) maximum above the finish floor or ground.
-
11B-902.4.2 Height
The tops of tables and counters shall be 26 inches (660 mm) minimum and 30 inches (762 mm) maximum above the finish floor or ground.
-
11B-902.4.2 Height
The tops of tables and counters shall be 26 inches (660 mm) minimum and 30 inches (762 mm) maximum above the finish floor or ground.
-
Openings: ADA Standard Section 302.3
Section 302.3 covers the current ADA Standards for floor and ground surface openings.
-
M305.2.3 Height (Section-by-Section Analysis)
transfer surface would be usable by patients with disabilities....