Signs and identification devices shall be field inspected after installation and approved by the enforcing agency prior to the issuance of a final certificate of occupancy per...
Search Results "Tactilely Discernible"
Commonly Searched Documents
-
11B-703.1.1.2 Inspection
-
§27.71(k)(6)(iv)(A) Contrast.
However, tactile symbols required by (k)(6)(iv)(B) are not required to comply with paragraph (k)(6)(iv)(A) of this section....
-
§ 27.71(k)(6)(iv)(A) Contrast
However, tactile symbols required by (k)(6)(iv)(B) are not required to comply with paragraph (k)(6)(iv)(A) of this section....
-
1007.6.5 Identification
Additionally, tactile signage complying with ICC A117.1 shall be located at each door to an area of refuge....
-
1003.2.13.5.5 Identification
Additionally, tactile signage complying with ICC A117.1 shall be located at each door to an area of refuge....
-
Mounting Height and Location
Section 703.4 covers the mounting height and location of signs with tactile characters....
-
11B-216.1 General
signs identifying permanent rooms and spaces, directional and informational signs (except those relating to accessible means of egress), and entrance signs are not required to comply with tactile...
-
Designations: ADA Standard Section 216.2
Section 216.2 covers scoping requirements in the current ADA Standards for sign designations.
-
Stroke Thickness: ADA Standard Section 703.5.7
Stroke thickness of the uppercase letter “I” shall be 10 percent minimum and 30 percent maximum of the height of the character.
-
11B-703.5.7 Stroke thickness
Stroke thickness of the uppercase letter “I” shall be 10 percent minimum and 20 percent maximum of the height of the character. [2010 ADA Standards] 703.5.7 Stroke Thickness....
- Figure 407.2.3.1 Floor Designations on Jambs of Elevator Hoistway Entrances – Drawing from the U.S. Access Board
-
407.2.3.1 Floor Designation
Floor designations shall be provided in both tactile characters and braille. Tactile characters shall be 2 inches (51 mm) high minimum....
-
407.2.3.1 Floor Designation
Floor designations shall be provided in both tactile characters and braille. Tactile characters shall be 2 inches (51 mm) high minimum....
-
407.2.3.1 Floor Designation
Floor designations shall be provided in both tactile characters and braille. Tactile characters shall be 2 inches (51 mm) high minimum....
- Access Board: Tactile Sign Raised Character Requirements
-
703.4 Installation Height and Location
Signs with tactile characters shall comply with 703.4....
-
703.4 Installation Height and Location
Signs with tactile characters shall comply with 703.4....
-
Character Proportions: ADA Standard Section 703.5.4
Characters shall be selected from fonts where the width of the uppercase letter “O” is 55 percent minimum and 110 percent maximum of the height of the uppercase letter “I”.
-
Character Spacing: ADA Standard Section 703.5.8
Character spacing shall be measured between the two closest points of adjacent characters, excluding word spaces. Spacing between individual characters shall be 10 percent minimum...
-
11B-703.5.4 Character proportions
Characters shall be selected from fonts where the width of the uppercase letter “O” is 60 percent minimum and 110 percent maximum of the height of the uppercase letter “I”. [2010...
-
11B-703.5.8 Character spacing
Character spacing shall be measured between the two closest points of adjacent characters, excluding word spaces. Spacing between individual characters shall be 10 percent minimum...
-
11B-703.4 Installation height and location
Signs with tactile characters shall comply with Section 11B-703.4....
-
11B-703.4 Installation height and location
Signs with tactile characters shall comply with Section 11B-703.4....