An eggshell finish (11 to 19 degree gloss on 60 degree glossimeter) is recommended. Research indicates that signs are more legible for persons with low vision when characters...
Search Results "Tactile Exit Signage"
-
A4.30.5 Finish and Contrast
-
1007.6.5 Identification
Where exit sign illumination is required by Section 1011.2, the area of refuge sign shall be illuminated....
-
SECTION 1011 EXIT SIGNS
SECTION 1011 EXIT SIGNS...
-
1011.4 Raised character and Braille exit signs
1011.4 Raised character and Braille exit signs. Tactile exit signs shall be required at the following locations:...
-
1011.4, Item 1
Each grade-level exterior exit door that is required to comply with Section 1011.1 shall be identified by a tactile exit sign with the word, “EXIT.”...
-
1011.4, Item 2
Each exit door that is required to comply with Section 1011.1, and that leads directly to a grade-level exterior exit by means of a stairway or ramp shall be identified by a tactile exit...
-
1011.4, Item 2.1
2.1 “EXIT STAIR DOWN”...
-
1011.4, Item 2.2
2.2 “EXIT RAMP DOWN”...
-
1011.4, Item 2.3
2.3 “EXIT STAIR UP”...
-
1011.4, Item 2.4
2.4 “EXIT RAMP UP”...
-
1011.4, Item 3
Each exit door that is required to comply with Section 1011.1, and that leads directly to a grade-level exterior exit by means of an exit enclosure or an exit passageway shall be identified...
-
1011.4, Item 4
Each exit access door from an interior room or area to a corridor or hallway that is required to comply with Section 1011.1, shall be identified by a tactile exit sign with the words “EXIT...
-
1011.4, Item 5
Each exit door through a horizontal exit that is required to comply with Section 1011.1 shall be identified by a sign with the words, “TO EXIT.”...
-
Raised character and Braille exit signs
Raised character and Braille exit signs shall comply with Chapter 11A, Section 1143A or Chapter 11B, Sections 11B-703.1, 11B-703.2, 11B-703.3 and 11B-703.5....
-
1022.9 Stairway identification signs
At the exit discharge level, the sign shall include a raised five pointed star located to the left of the identifying floor level....
-
11B-216 SIGNS
-
11B-216.1 General
The substantive difference between the 2013 CBC and 2010 ADAS scoping for signage at parking facilities is that signs identifying permanent rooms and spaces, directional and informational...
-
11B-216.2 Designations
Tactile text descriptors are required for pictograms that are provided to label or identify a permanent room or space....
-
11B-216.4.1 Exit doors
Signs required by Chapter 10, Section 1011.4 at doors to exit passageways, exit discharge, and exit stairways shall comply with Sections 11B-703.1 _|Signs; General|_ 11B-703.2 _|Signs; Raised...
-
11B-703 SIGNS
-
11B-703.1 General
Where both visual and tactile characters are required, either one sign with both visual and tactile characters, or two separate signs, one with visual, and one with tactile characters, shall...
-
11B-703.1.1 Plan review and inspection
Signs as specified in Section 11B-703, or in other sections of this code, when included in the construction of new buildings or facilities, or when included, altered or replaced due...
-
11B-703.1.1.2 Inspection
Signs and identification devices shall be field inspected after installation and approved by the enforcing agency prior to the issuance of a final certificate of occupancy per...
-
11B-703.4 Installation height and location
Signs with tactile characters shall comply with Section 11B-703.4....