A transfer space of 60 inches (1524 mm) minimum by 60 inches (1524 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer platform surface and shall...
Search Results "Side Transfer Surface"
-
11B-1009.5.2 Transfer space
-
5.4.8 Transfer Support Gripping Surface Hazard Recommendation for M301 and M302
5.4.8 Transfer Support Gripping Surface Hazard Recommendation for M301 and M302 Description: Gripping surface hazards are sharp or abrasive elements that prevent an individual from sufficiently...
-
M302.2.1 Adjustability
Transfer surfaces shall be adjustable in height measured from the floor to the top of the uncompressed transfer surface and shall provide the following: A....
-
M301.2.2 Sunset Provision (Section-by-Section Analysis)
(Significant Changes – Transfer Surface Adjustability), this is a new provision that was added to the final rule in conjunction with the new requirement of a low height range in M301.2.1...
-
Transfer Supports (M301.3.1, M302.3.1, and M305.2)
M301.3.1 and M302.3.1 would require transfer supports to be provided for use with the transfer sides....
-
11B-404.2.10 Door and gate surfaces
Swinging door and gate surfaces within 10 inches (254 mm) of the finish floor or ground measured vertically shall have a smooth surface on the push side extending the full width of the door...
-
11B-404.2.10 Door and gate surfaces
Swinging door and gate surfaces within 10 inches (254 mm) of the finish floor or ground measured vertically shall have a smooth surface on the push side extending the full width of the door...
-
Figure M3: Overview of M302 Diagnostic Equipment for Use by a Patient in a Seated Position
[See subsections ...]
-
11B-1002.5.3 Transfer entry
Where openings are provided for transfer to amusement ride seats, the openings shall provide clearance for transfer from a wheelchair or mobility aid to the amusement ride seat....
-
11B-1002.5.3 Transfer entry
Where openings are provided for transfer to amusement ride seats, the openings shall provide clearance for transfer from a wheelchair or mobility aid to the amusement ride seat....
-
Exposed Surfaces: ADA Standard Section 804.3.3
There shall be no sharp or abrasive surfaces under the work surface counters....
-
M302.2.2 Sunset Provision (Section-by-Section Analysis)
(Significant Changes – Transfer Surface Adjustability), this is a new provision added to the final rule in conjunction with the new requirement of a low height range in M302.2.1....
-
Transfer Device
Equipment designed to facilitate the transfer of a person from a wheelchair or other mobility aid to and from an amusement ride seat....
-
TRANSFER DEVICE
[DSA-AC] Equipment designed to facilitate the transfer of a person from a wheelchair or other mobility aid to and from an amusement ride seat....
-
TRANSFER DEVICE
[DSA-AC] Equipment designed to facilitate the transfer of a person from a wheelchair or other mobility aid to and from an amusement ride seat....
-
11B-404.2.4 Maneuvering clearances
Maneuvering clearances shall extend the full width of the doorway and the required latch side or hinge side clearance. Exception: Reserved....
-
11B-404.2.4 Maneuvering clearances
Maneuvering clearances shall extend the full width of the doorway and the required latch side or hinge side clearance. Exception: Reserved....
-
M305.2.1 Location (Section-by-Section Analysis)
, and requiring the transfer support to be located on the side of the transfer surface opposite the transfer side....
-
5.4.2 Transfer Support Length for M301 and M302
The transfer support would extend horizontally the entire depth of the transfer surface and would be 15 inches minimum in length....
-
How To Video: Transfer from Floor to Chair
Requires the Registered User plan or above. Login!
-
Transfer Platform
Transfer Platform Each transfer system must have a platform on the deck surface so users can maneuver on and off the system from their mobility device or wheelchair....
-
11B-403.2 Floor or ground surface
Floor or ground surfaces shall comply with Section 11B-302....
-
11B-403.2 Floor or ground surface
Floor or ground surfaces shall comply with Section 11B-302....
-
5.4.7 Transfer Support Gripping Surface Clearance for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
5.4.7 Transfer Support Gripping Surface Clearance for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position....