Where counters or teller windows have security glazing to separate personnel from the public, a method to facilitate voice communication shall be provided....
Search Results "Separation"
-
11B-904.6 Security glazing
-
11B-904.6 Security glazing
Where counters or teller windows have security glazing to separate personnel from the public, a method to facilitate voice communication shall be provided....
-
§104.52(a)(5)
(5) Provide different or separate benefits or services to handicapped persons except where necessary to provide qualified handicapped persons with benefits and services that are as effective...
-
231.4.2 Partitions
Where solid partitions or security glazing separate visitors from detainees, at least one of each type of cubicle or counter partition shall comply with 904.6....
-
11B-231.4.2 Partitions
Where solid partitions or security glazing separate visitors from detainees at least one of each type of cubicle or counter partition shall comply with Section 11B-904.6....
-
4.3.11.1(5)
(5) A portion of a stairway landing within an exit enclosure which is vented to the exterior and is separated from the interior of the building with not less than one-hour fire-resistive...
-
Garage Parking
At sites that also include surface lots, a garage is treated as a separate parking facility for scoping purposes....
-
11B-231.4.2 Partitions
Where solid partitions or security glazing separate visitors from detainees at least one of each type of cubicle or counter partition shall comply with Section 11B-904.6....
-
11B-703.5.9 Line spacing
Spacing between the baselines of separate lines of characters within a message shall be 135 percent minimum and 170 percent maximum of the character height....
-
11B-231.4.2 Partitions
Where solid partitions or security glazing separate visitors from detainees at least one of each type of cubicle or counter partition shall comply with Section 11B-904.6....
-
1630.2(p)(2)(IV)
(IV) The type of operation or operations of the covered entity, including the composition, structure and functions of the workforce of such entity, and the geographic separateness and administrative...
-
703.2.8 Line Spacing
Spacing between the baselines of separate lines of raised characters within a message shall be 135 percent minimum and 170 percent maximum of the raised character height....
-
12111(10)(B)(IV)
(IV) the type of operation or operations of the covered entity, including the composition, structure, and functions of the workforce of such entity; the geographic separateness, administrative...
-
703.2.8 Line Spacing
Spacing between the baselines of separate lines of raised characters within a message shall be 135 percent minimum and 170 percent maximum of the raised character height....
-
232.5.2 Partitions
Where solid partitions or security glazing separate visitors from detainees or inmates, at least one of each type of cubicle or counter partition shall comply with 904.6....
-
12111(10)(B)(iv)
(iv) the type of operation or operations of the covered entity, including the composition, structure, and functions of the workforce of such entity; the geographic separateness, administrative...
-
§1630.2(p)(2)(iv)
(iv) The type of operation or operations of the covered entity, including the composition, structure and functions of the workforce of such entity, and the geographic separateness and administrative...
-
4.34.7 LAUNDRY FACILITIES
If laundry equipment is provided within individual accessible dwelling units, or if separate laundry facilities serve one or more accessible dwelling units, then they shall meet the requirements...
-
§ 37.125(g)(2)
(2) The process shall include an opportunity to be heard and to present information and arguments, separation of functions (i.e., a decision by a person not involved with the initial decision...
-
11B-703.2.8 Line spacing
Spacing between the baselines of separate lines of raised characters within a message shall be 135 percent minimum and 170 percent maximum of the raised character height....
-
Ground Level: ADA Standard Section 1008.2.4.1
The clear width of accessible routes shall be permitted to be 36 inches (915 mm) minimum for a distance of 60 inches (1525 mm) maximum provided that multiple reduced width segments are separated...
-
11B-604.8.1.5 Grab bars
Where separate grab bars are required on adjacent walls at a common mounting height, an L-shaped grab bar meeting the dimensional requirements of Sections 11B-604.5.1 and 11B-604.5.2 shall...
-
11B-1008.2.4.1 Ground level
The clear width of accessible routes shall be permitted to be 36 inches (914 mm) minimum for a distance of 60 inches (1524 mm) maximum provided that multiple reduced width segments are separated...
-
11B-211.2 Minimum number
Exception: Where a single drinking fountain complies with Sections 11B-602.1 through 11B-602.9, it shall be permitted to be substituted for two separate drinking fountains....