5.8.3.1 Breast Platform Height. The height of the top of the breast platform should be decreased to 26 inches above the floor. The upper height range for the breast platform was not...
Search Results "Patient Seated in Wheelchair"
-
5.8.3.1 Breast Platform Height
-
5.8.2.8 Knee and Toe Clearance Recommendations Summary
5.8.2.8 Knee and Toe Clearance Recommendations Summary Ultimately, all of the knee and toe clearance recommendations in sections 5.8.2.1 – 5.8.2.7 are summarized below, in Figure...
-
5.8.2.6 Clearance Depth at Toe Height Above the Ground
5.8.2.6 Clearance Depth at Toe Height Above the Ground. The toe clearance depth should be 22 inches minimum at toe height.
-
5.8.3 Breast Platform
5.8.3 Breast Platform
-
5.8.2.3 Overall Knee and Toe Clearance Recommendation
5.8.2.3 Overall Knee and Toe Clearance Recommendation The Committee recommends increasing the overall knee and toe space to 28 inches minimum. Rationale for the...
-
5.8.2.6 Clearance Depth at Toe Height above the ground Recommendation
5.8.2.6 Clearance Depth at Toe Height above the ground Recommendation The Committee recommends 22 inches minimum clearance depth at toe height. Rationale for...
-
5.8.2.3 Overall Knee and Toe Clearance
5.8.2.3 Overall Knee and Toe Clearance. The overall knee and toe space should be increased to a minimum of 28 inches.
-
Figure M6: M303.2.4 Knee and Toe Clearance
[See subsections ...]
-
221.2 Wheelchair Spaces
221.2 Wheelchair Spaces. Wheelchair spaces complying with 221.2 shall be provided in assembly areas with fixed seating....
-
M302.1 General
Where diagnostic equipment is used by patients in a seated position, it shall comply with M302....
- Barrier Free Lifts L101-400 Series LEXA Professional Patient Lift
-
5. Edge Protection
The Access Board sought public input with question 30 in the MDE NPRM preamble, on whether there is diagnostic equipment with wheelchair spaces on raised platforms that does not provide...
-
Clearances Around Gripping Surfaces
The Access Board is considering whether 1½ inches minimum clearance around the gripping surface would be appropriate for transfer supports on diagnostic equipment used by patients in a supine...
-
M303.3.3 Ramped (Section-by-Section Analysis)
The MDE NPRM proposed that for equipment with a change in level at the entry of a wheelchair space, level changes greater than ½ inch high would be required to be ramped and comply with...
-
L-Shaped Seats: ADA Standard Section 610.3.2
Section 610.3.2 covers the current ADA Standards for L-shaped shower compartment seats.
-
3. Exception to Ramp Running Slope
The MDE NPRM proposed that where there is a change in level at the entry of a wheelchair space that is greater than 1½ inches, the entry shall be ramped and have a running slope not steeper...
-
221.2.1.4 Team or Player Seating
221.2.1.4 Team or Player Seating. At least one wheelchair space complying with 802.1 shall be provided in team or player seating areas serving areas of sport activity....
-
F221.2 Wheelchair Spaces
Wheelchair spaces complying with F221.2 shall be provided in assembly areas with fixed seating....
-
221.2 Wheelchair Spaces
Wheelchair spaces complying with 221.2 shall be provided in assembly areas with fixed seating....
-
M302 Diagnostic Equipment Used by Patients in Seated Position
[See subsections ...]
-
M302 Diagnostic Equipment Used by Patients in Seated Position
[See subsections ...]
-
F221.2.1.4 Team or Player Seating
At least one wheelchair space complying with 802.1 shall be provided in team or player seating areas serving areas of sport activity....
-
221.2.1.4 Team or Player Seating
At least one wheelchair space complying with 802.1 shall be provided in team or player seating areas serving areas of sport activity....
-
6.1
6.1 Wheelchair spaces shall have at least one fixed companion fixed seat adjacent to each wheelchair space....