1136A.2 Switch and control heights
-
1136A.2 Switch and control heights
Controls or switches intended to be used by the occupant of the room or area to control lighting and receptacle outlets, appliances, alarms or cooling, heating and ventilating equipment...
-
T505.3 Location of Operable Parts
Operable parts shall be located so that they are reachable by passengers using wheelchair when parked in a clear space 30 inches (760 mm) wide minimum and 48 inches (1220 mm) long minimum...
-
4.34.2(9)
(9) All controls in accessible spaces shall comply with 4.27....
-
Viewing Scopes [1011.2, 1011.3, and 1011.8]
The other operable parts of viewing scopes, such as handles or levers, must be located between 15 and 48 inches above the ground and be operable using one hand without tightly grasping,...
-
Height [4.27.3]
Height [4.27.3] The operable portions of controls and operating mechanisms must be within established reach ranges for either a forward or side reach as required in 4.2.5 and 4.2.6 (see...
-
6.14.2 Gate Hardware
Gate hardware shall comply with operable controls requirements in ABAAS section 309.4 and 404.2.7....
-
407.12.3.2.1 Height (Section-by-Section Analysis)
407.12.3.2.1 Height (Section-by-Section Analysis) This section, presented in tabular form (Table 407.12.3.2.1), proposes alternative maximum heights for operable parts with obstructed...
-
§ 382.57(c)(3) Operable parts
(3) Operable parts. Operable parts must comply with section 309 of the 2010 ADA Standards, and the following requirements:...
-
407.12.3.2.1 Height
The height of the operable part shall conform to Table 407.12.3.2.1....
-
6f.
Are the controls and operating mechanisms usable with one hand without tight grasping, pinching, or twisting?...
-
404.2.7 Door and Gate Hardware
Handles, pulls, latches, locks, and other operable parts on doors and gates shall comply with 309.4....
-
407.1 General
Where provided, operable parts used in the normal operation of ICT shall conform to 407....
-
f-vi
Are the controls and operating mechanisms usable with one hand without tight grasping, pinching, or twisting? [ADA Standards §§ 4.11.2, 4.27.4] Yes No...
-
6e.
Are the controls and operating mechanisms mounted no more than 54 inches above the floor for a side reach or 48 inches for a forward reach? Yes _____ No _____...
-
f-v
Are the controls and operating mechanisms mounted no more than 54 inches above the floor for a side reach or 48 inches for a forward reach?...
-
M307.2 Tactilely Discernible
Operable parts shall be tactilely discernible without activation....
-
M307.2 Tactilely Discernible
Operable parts shall be tactilely discernible without activation....
-
407.1 General
Where provided, operable parts of ICT shall conform to 407....
-
Reach Ranges and Operable Parts
REACH RANGES AND OPERABLE PARTS Forward and side reach 11B-308.2/3 Over projections 11B-308.2.2/3.2...
-
Reach Ranges and Operable Parts
REACH RANGES AND OPERABLE PARTS Forward and side reach 11B-308.2/3 Over projections 11B-308.2.2/3.2...
-
11B-707.9.1, 11B-707.9.2 Point-of-sale devices
Removes and relocates to 11B-707.3 requirements specific to operable parts....
-
T304.3 Location
Operable parts provided at a wheelchair space shall be located adjacent to the wheelchair space 24 inches (610 mm) minimum and 36 inches (915 mm) maximum from the rear of the wheelchair...
-
11B-228.3.1.2 Operable parts