Section 242.3 covers scoping requirements in the current ADA Standards for wading pools.
Search Results "Non-Fixed Pool Lift"
-
Wading Pools: ADA Standard Section 242.3
-
11B-607.6 Shower spray unit and water
A shower spray unit with a hose 59 inches (1499 mm) long minimum that can be used both as a fixed-position shower head and as a hand-held shower shall be provided....
-
11B-607.6 Shower spray unit and water
A shower spray unit with a hose 59 inches (1499 mm) long minimum that can be used both as a fixed-position shower head and as a hand-held shower shall be provided....
-
Shower Spray Unit and Water: ADA Standard Section 607.6
Section 607.5 covers the current ADA Standards for bathtub shower spray units and the water temperature of the spray units.
-
11B-1009.2.2 Seat location
In the raised position, the centerline of the seat shall be located over the deck and 16 inches (406 mm) minimum from the edge of the pool....
-
11B-1009.2.2 Seat location
In the raised position, the centerline of the seat shall be located over the deck and 16 inches (406 mm) minimum from the edge of the pool....
-
1009.2.2 Seat Location
In the raised position, the centerline of the seat shall be located over the deck and 16 inches (405 mm) minimum from the edge of the pool....
-
11B-242.3 Wading pools
At least one accessible means of entry shall be provided for wading pools. Accessible means of entry shall comply with sloped entries complying with Section 11B-1009.3....
-
11B-242.3 Wading pools
At least one accessible means of entry shall be provided for wading pools. Accessible means of entry shall comply with sloped entries complying with Section 11B-1009.3....
-
1009 Swimming Pools, Wading Pools, and Spas
1009 Swimming Pools, Wading Pools, and Spas...
-
242 Swimming Pools, Wading Pools, and Spas
242 Swimming Pools, Wading Pools, and Spas...
- Integralift Fixed Ceiling Lift
-
3. Swimming Pools
Hamilton Pool is the closest pool to her home. RT 1393:2-3. Kirola's only complaint regarding that pool is that she cannot use the children's slide because it lacks a lift....
-
Operable Parts: ADA Standard Section 410.5
Section 410.5 covers the current ADA Standards for operable parts of the platform lift controls.
-
1009.2.3 Clear Deck Space
Figure 1009.2.3 Clear Deck Space at Pool Lifts...
-
11B-1009.2.3 Clear deck space
FIGURE 11B-1009.2.3 CLEAR DECK SPACE AT POOL LIFTS...
-
1009.2.3 Clear Deck Space
Figure 1009.2.3 Clear Deck Space at Pool Lifts...
-
Shower Spray Unit and Water: ADA Standard Section 608.6
Section 608.6 covers the current ADA Standards for the shower spray units and water in shower compartments.
-
Catch Pools
Catch Pools A catch pool is a body of water where water slide flumes drop users into the water. An accessible means of entry or exit is not required into the catch pool....
-
11B-608.6 Shower spray unit and water
A shower spray unit with a hose 59 inches (1499 mm) long minimum that can be used both as a fixed-position shower head and as a hand-held shower shall be provided....
-
11B-608.6 Shower spray unit and water
A shower spray unit with a hose 59 inches (1499 mm) long minimum that can be used both as a fixed-position shower head and as a hand-held shower shall be provided....
-
11B-609.2.2 Non-circular cross section
Grab bars with non-circular cross sections shall have a cross-section dimension of 2 inches (51 mm) maximum and a perimeter dimension of 4 inches (102 mm) minimum and 4.8 inches (122 mm)...
-
11B-609.2.2 Non-circular cross section
Grab bars with non-circular cross sections shall have a cross-section dimension of 2 inches (51 mm) maximum and a perimeter dimension of 4 inches (102 mm) minimum and 4.8 inches (122 mm)...
-
Platform Lifts: ADA Standard Section 410