Outdoor stairs and their approaches shall be designed so that water will not accumulate on walking surfaces.
Search Results "Exterior Exit Stairway"
Commonly Searched Documents
- 
    
  
  4.9.6 OUTDOOR CONDITIONS
  
- 
    
  
  1009.7.2 Separation
  Exterior walls separating the exterior area of assisted rescue from the interior of the building shall have a minimum fire-resistance rating of 1 hour, rated for exposure to fire from the... 
- 
    
  
  1009.7.2 Separation
  Exterior walls separating the exterior area of assisted rescue from the interior of the building shall have a minimum fire-resistance rating of 1 hour, rated for exposure to fire from the... 
- 
    
  
  1007.7.4 Separation
  Exterior walls separating the exterior area of assisted rescue from the interior of the building shall have a minimum fire-resistance rating of 1 hour, rated for exposure to fire from the... 
- 
    
  
  1007.7 Exterior area for assisted rescue
  1007.7 Exterior area for assisted rescue. Exterior areas for assisted rescue shall be accessed by an accessible route from the area served.... 
- 
    
  
  Stairways [§504]
  Stairways [§504] Requirements for stairways address treads and risers, surfaces, nosings, and handrails.... 
- 
    
  
  217.4.4 Exterior Site Requirement
  Where four or more public pay telephones are provided on an exterior site, at least one public TTY shall be provided on the site.... 
- 
    
  
  Raised character and Braille exit signs
  Raised character and Braille exit signs shall comply with Chapter 11A, Section 1143A or Chapter 11B, Sections 11B-703.1, 11B-703.2, 11B-703.3 and 11B-703.5.... 
- 
    
  
  11B-705.1.2.2.2.2 Two entrance/exit points
  Where the turning space has two entrance/exit points other than the sloped ramp segments, detectable warnings shall be 36 inches (914 mm) deep at both entrance/ exit points, as measured... 
- 
    
  
  1132A.2 Interior doors and secondary exterior doors
  1132A.2 Interior doors and secondary exterior doors.... 
- 
    
  
  1003.2.13.7.1 Openness
  The exterior area of refuge shall be at least 50 percent open, and the open area above the guards shall be so distributed as to minimize the accumulation of smoke or toxic gases.... 
- 
    
  
  1007.8.1 Openness
  The exterior area for assisted rescue shall be at least 50 percent open, and the open area above the guards shall be so distributed as to minimize the accumulation of smoke or toxic gases... 
- 
    
  
  Egress Signage
  Section 216.4 provides specific requirements for means of egress, including exit doors, areas of refuge, and directional signs.... 
- 
    
  
  1009.7.3 Openness
  The exterior area for assisted rescue shall be open to the outside air.... 
- 
    
  
  1009.7.3 Openness
  The exterior area for assisted rescue shall be open to the outside air.... 
- 
    
  
  1007.7.5 Openness
  The exterior area for assisted rescue shall be open to the outside air.... 
- 
    
  
  1007.7.2 Outdoor facilities
  Where exit access from the area serving outdoor facilities is essentially open to the outside, an exterior area of assisted rescue is permitted as an alternative to an area of refuge.... 
- 
    
  
  11B-217.4.4 Exterior site requirement
  Where four or more public pay telephones are provided on an exterior site, at least one public TTY shall be provided on the site.... 
- 
    
  
  11B-217.4.4 Exterior site requirement
  Where four or more public pay telephones are provided on an exterior site, at least one public TTY shall be provided on the site.... 
- 
    
  
  1011.4, Item 5
  Each exit door through a horizontal exit that is required to comply with Section 1011.1 shall be identified by a sign with the words, “TO EXIT.”... 
- 
    
  
  1013.4, Item 5
  Each exit door through a horizontal exit that is required to comply with Section 1013.1 shall be identified by a sign with the words, “TO EXIT.” ... 
- 
    
  
  11B-206.2.3.1 Stairs and escalators in existing buildings
  In alterations and additions, where an escalator or stair is provided where none existed previously and major structural modifications are necessary for the installation, an... 
- 
    
  
  Entrance
  As used in the Guidelines, "entrance" refers to an exterior entry door.... 
- 
    
  
  1011.4, Item 4
  Each exit access door from an interior room or area to a corridor or hallway that is required to comply with Section 1011.1, shall be identified by a tactile exit sign with the words “EXIT... 