At exterior doors serving Groups F, H, R-2 and S and where such doors are not part of an adaptable or accessible route or, not required to be accessible by Chapter 11A or 11B of the California...
Search Results "Exterior Door"
Commonly Searched Documents
-
1010.1.4 Floor elevation
-
4.13.10* Door Closers
If a door has a closer, then the sweep period of the closer shall be adjusted so that from an open position of 70 degrees, the door will take at least 3 seconds to move to a point 3 in (...
-
4.13.10* DOOR CLOSERS
If a door has a closer, then the sweep period of the closer shall be adjusted so that from an open position of 70 degrees, the door will take at least 3 seconds to move to a point 3 in (...
-
11B-504.3 Open risers
On exterior stairways, an opening of not more than ½ inch (12.7 mm) may be permitted between the base of the riser and the tread. 2. ...
-
11B-504.3 Open risers
On exterior stairways, an opening of not more than ½ inch (12.7 mm) may be permitted between the base of the riser and the tread. 2. ...
-
Automatic Doors and Power Assisted Doors [4.13.12]
Automatic Doors and Power Assisted Doors [4.13.12] Automated doors are classified by industry standards according to the level of force produced by the door opening....
-
Clear Width: ADA Standard Section 404.3.1
Section 404.3.1 covers the current ADA Standards for clear width at automatic and power-assisted doors and gates.
-
11B-404.2.4.3 Recessed doors and gates
clearances for forward approach shall be provided when any obstruction within 18 inches (457 mm) of the latch side at an interior doorway, or within 24 inches (610 mm) of the latch side of an exterior...
-
11B-404.2.4.3 Recessed doors and gates
clearances for forward approach shall be provided when any obstruction within 18 inches (457 mm) of the latch side at an interior doorway, or within 24 inches (610 mm) of the latch side of an exterior...
-
11B-404.2.4.3 Recessed doors and gates
clearances for forward approach shall be provided when any obstruction within 18 inches (457 mm) of the latch side at an interior doorway, or within 24 inches (610 mm) of the latch side of an exterior...
-
404.3.4 Doors in Series and Gates in Series
Doors in series and gates in series shall comply with 404.2.6....
-
404.3.4 Doors in Series and Gates in Series
Doors in series and gates in series shall comply with 404.2.6....
-
F217.4.4 Exterior Site Requirement
Where four or more public pay telephones are provided on an exterior site, at least one public TTY shall be provided on the site....
-
5.1.9 Doors
Where provided, doors shall comply with ABAAS section 404. The door shall not swing into or otherwise obstruct the clear floor or ground space or the turning space required by 5.1.4....
-
404.3.7 Revolving Doors, Revolving Gates, and Turnstiles
404.3.7 Revolving Doors, Revolving Gates, and Turnstiles. Revolving doors, revolving gates, and turnstiles shall not be part of an accessible route....
-
1009.7 Exterior areas for assisted rescue
Exterior areas for assisted rescue shall be accessed by an accessible route from the area served....
-
1009.7 Exterior areas for assisted rescue
Exterior areas for assisted rescue shall be accessed by an accessible route from the area served....
-
Can elevator doors close sooner than the minimum opening time specified when users activate door close?
User activation of door close (or automatic operation) cannot reduce the initial opening time of doors (3 seconds minimum) or the minimum door signal timing (based on 1.5/ ft/s travel speed...
-
A4.13.11(1) Hinged doors
(1) Hinged doors: Force applied perpendicular to the door at the door opener or 30 in (760 mm) from the hinged side, whichever is farther from the hinge....
-
A4.13.11(1) Hinged doors
(1) Hinged doors: Forced applied perpendicular to the door at the door opener or 30 in (760 mm) from the hinged side, whichever is farther from the hinge....
-
11B-404.2.7 Door and gate hardware
Exceptions: Existing locks shall be permitted in any location at existing glazed doors without stiles, existing overhead rolling doors or grilles, and similar existing doors or grilles...
-
407.3 Elevator Door Requirements
407.3 Elevator Door Requirements. Hoistway and car doors shall comply with 407.3....
-
404.2.2 Double-Leaf Doors and Gates
404.2.2 Double-Leaf Doors and Gates. At least one of the active leaves of doorways with two leaves shall comply with 404.2.3 and 404.2.4....