Emergency two-way communication systems shall comply with Section 11B-308....
Search Results "Emergency Shelter"
-
11B-407.4.9 Emergency communication
-
11B-407.4.9 Emergency communication
Emergency two-way communication systems shall comply with Section 11B-308....
-
11B-1006.4 Weather shelters
A clear floor or ground space 60 inches (1524 mm) minimum by 96 inches (2438 mm) minimum shall be provided within weather shelters....
-
11B-1006.4 Weather shelters
A clear floor or ground space 60 inches (1524 mm) minimum by 96 inches (2438 mm) minimum shall be provided within weather shelters....
-
C. Preparation – Advance Planning for Emergencies and Disasters
An emergency management plan is the all-important first step in ensuring an effective response to emergencies and disasters....
-
11B-409.4.7.1 Type
A telephone and emergency signal device shall be provided in the car....
-
11B-409.4.7.1 Type
A telephone and emergency signal device shall be provided in the car....
-
11B-409.4.7.2 Operable parts
The telephone and emergency signaling device shall comply with Sections 11B-309.3 and 11B-309.4....
-
11B-409.4.7.2 Operable parts
The telephone and emergency signaling device shall comply with Sections 11B-309.3 and 11B-309.4....
- Viking K-1600-EHFA Elevator Phone with Built-in Dialer and Digital Announcer
-
d-v
d-v. If a ramp is longer than 30 feet, is a level landing at least 60 inches long provided every 30 feet? [ADA Standards § 4.8.4] Yes No
-
H2
H2. Does the door to the toilet room provide at least 32 inches clear passage width when the door is open 90 degrees? [ADA Standards § 4.13.5] Yes No
-
H6
H6. If the entry has a vestibule, is there a 30-inch by 48-inch clear floor space inside the vestibule where a wheelchair or scooter user can be outside the door swing? [ADA...
-
H22
H22. Is a second horizontal grab bar at least 36 inches long securely mounted on the back wall with one end no more than 6 inches from the side wall 33 to 36 inches above the floor?...
-
f-vi
f-vi. Is there a level landing, at least 60 inches x 60 inches, when a ramp changes direction? [ADA Standards § 4.8.4] Yes No
-
H13
H13. Is the operating control (switch, lever, button, or pull) of at least one of each type of dispenser or built-in equipment no higher than 54 inches above the floor (if there is...
-
M2
M2. Does the door to the toilet room provide at least 32 inches clear passage width when the door is open 90 degrees? [ADA Standards § 4.13.5] Yes No
-
H17
H17. Is at least 9 inches of toe clearance provided under the front wall and at least one side wall of the toilet stall? [ADA Standards § 4.17.4] Yes No
-
H7
H7. Inside the toilet room, is there an area where a person who uses a wheelchair or other mobility device can turn around - either at least 60-inch diameter circle or a “T”-shaped...
-
H21
H21. Is a horizontal grab bar at least 40 inches long securely mounted on the adjacent side wall 33 to 36 inches above the floor with one end no more than 12 inches from the back...
-
M6
M6. Inside the room is there an area for a person who uses a wheelchair to turn around - either a 60-inch diameter circle or a “T”-shaped turn area? [ADA Standards §§ 4.22.3;...
-
M7
M7. If the door swings into the room, does the door swing not overlap the required clear floor space for the toilet or lavatory? [ADA Standards §§ 4.22.2;...
-
H16
H16. Is the toilet stall at least 60 inches wide and 56 inches deep (wall mounted toilet) or 59 inches deep (floor mounted toilet)? [ADA Standards § 4.17.3] Yes No If...
-
H26
H26. If there are 6 or more stalls in the restroom, is one of those stalls (in addition to the wider stall noted above) exactly 36 inches wide with an out swinging stall door that...