Toilet compartment doors, including door hardware, shall comply with Section 11B-404 except that if the approach is from the push side of the compartment door, clearance between the door...
Search Results "Doors in Series"
Commonly Searched Documents
-
11B-604.8.1.2 Doors
-
11B-604.8.1.2 Doors
Toilet compartment doors, including door hardware, shall comply with Section 11B-404 except that if the approach is from the push side of the compartment door, clearance between the door...
-
11B-404.2.8.1 Door closers and gate closers
Door closers and gate closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door to a position of 12 degrees from the latch is 5 seconds minimum...
-
11B-404.2.8.1 Door closers and gate closers
Door closers and gate closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door to a position of 12 degrees from the latch is 5 seconds minimum...
-
11B-411.3.5 Width
The width of elevator doors shall comply with Table 11B-407.4.1....
-
11B-404.2.8.1 Door closers and gate closers
Door closers and gate closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door to a position of 12 degrees from the latch is 5 seconds minimum...
-
1991 / 1994 ADA Standards - Plan Review Tool - Doors
1991 / 1994 ADA Standards - Plan Review Tool - Doors Click here to view/download the pdf, Page 1 of 2 (256 KB) Click here to view/download the pdf, Page 2 of 2 (272 KB) * * * *...
-
Is compliance on both sides of a door or gate required when it is usable only from one side?
No, compliance is not required on both sides of those doors or gates that can be used in one direction only. Compliance is required only on the usable side....
-
11B-409.3 Elevator doors
Hoistway doors, car doors, and car gates shall comply with Sections 11B-409.3 and 11B-404....
-
11B-409.3 Elevator doors
Hoistway doors, car doors, and car gates shall comply with Sections 11B-409.3 and 11B-404....
-
11B-409.3 Elevator doors
Hoistway doors, car doors, and car gates shall comply with Sections 11B-409.3 and 11B-404....
-
4.13.9* Door Hardware
Handles, pulls, latches, locks, and other operating devices on accessible doors shall have a shape that is easy to grasp with one hand and does not require tight grasping, tight pinching...
-
Doors at Entrances to Businesses
Doors at Entrances to Businesses Most entrances to stores and businesses use 36 inch wide doors that are wide enough to be accessible....
-
Door Hardware [4.13.9]
Door Hardware [4.13.9] Hardware used to operate doors, including handles, pulls, latches and locks, must have a shape that is "easy to grasp with one hand" and does not require tight...
-
1010.1.6 Thresholds
or landing for other doors....
-
Error/Omission: The shape of the door hardware requires tight grasping, pinching, and twisting of the wrist to use.
Doors Error/Omission: The shape of the door hardware requires tight grasping, pinching, and twisting of the wrist to use....
-
4.1.3(7) Doors
(7) Doors:...
-
4.22.2 Doors
All doors to accessible toilet rooms shall comply with 4.13. Doors shall not swing into the clear floor space required for any fixture....
-
4.22.2 DOORS
All doors to accessible toilet rooms shall comply with 4.13. Doors shall not swing into the clear floor space required for any fixture....
-
R218 Doors, Doorways, and Gates
R218 Doors, Doorways, and Gates. Where provided at pedestrian facilities, doors, doorways, and gates shall comply with section 404 of Appendix D to 36 CFR part 1191....
-
11B-604.8.1.1.1 Maneuvering space with in-swinging door
In a wheelchair accessible compartment with an in-swinging door, a minimum 60 inches (1524 mm) wide by 36 inches (914 mm) deep maneuvering space shall be provided in front of the clearance...
-
SECTION 1010 DOORS, GATES AND TURNSTILES
[DSA-AC] In addition to the requirements of this section, means of egress, which provide access to, or egress from, buildings or facilities where accessibility is required for...
-
Common Problems with Entrances and Doors
Common Problems with Entrances and Doors Ø Each leaf of a set of double doors is often too narrow to be used independently by someone who uses a wheelchair....
-
Door Closing Speed Tool
Door Closing Speed Tool This handy tool was developed by Evan Terry Associates to assist its surveyors in measuring door closing speed....