Detectable warnings shall consist of a surface of truncated domes and shall comply with 705. Figure 705.1 Size and Spacing of Truncated Domes...
Search Results "Detectable Directional Texture"
-
705.1 General
-
R305.1 General
Detectable warning surfaces shall consist of truncated domes aligned in a square or radial grid pattern and shall comply with R305....
-
3.3 Guidance on the Visual Properties of Detectable Warnings
On dark sidewalks (e.g. asphalt) use light colored detectable warnings with a high reflectance fact or to provide light-on-dark contrast rather than using darker detectable warnings to provide...
-
Truncated Domes
The detectable warning criteria specify a pattern of evenly-spaced truncated domes....
- Takeform Fusion Signage Floor Directional Type B
-
Doors to Hazardous Areas (Reserved) [4.29.3] and Stairs (Reserved) [4.29.4]
Doors to Hazardous Areas (Reserved) [4.29.3] and Stairs (Reserved) [4.29.4] In the absence of a clear consensus on the need or specification for detectable warnings at doors and stairs...
-
Detectable Warning Surfaces on Boarding Platforms Used by Buses and Rail Vehicles, and Boarding and Alighting Areas Used by Rail Vehicles (Section-by-Section Analysis)
Detectable Warning Surfaces on Boarding Platforms Used by Buses and Rail Vehicles, and Boarding and Alighting Areas Used by Rail Vehicles (Section-by-Section Analysis) The 1991 ADAAG...
-
TACTILE WARNING
A standardized surface texture applied to or built into walking surfaces or other elements to warn visually impaired people of hazards in the path of travel....
-
11B-705.1.1.2 Dome spacing
Truncated domes in a detectable warning surface shall have a center-to-center spacing of 2.3 inches (58 mm) minimum and 2.4 inches (61 mm) maximum, and a base-to-base spacing of 0.65 inch...
- Takeform Fusion Signage Floor Directional Type B.2
-
11B-705.1.1.2 Dome spacing
Truncated domes in a detectable warning surface shall have a center-to-center spacing of 2.3 inches (58 mm) minimum and 2.4 inches (61 mm) maximum, and a base-to-base spacing of 0.65 inch...
-
11B-705.1.1.2 Dome spacing
Truncated domes in a detectable warning surface shall have a center-to-center spacing of 2.3 inches (58 mm) minimum and 2.4 inches (61 mm) maximum, and a base-to-base spacing of 0.65 inch...
-
11B-247.1.2.1 Platform edges
Platform boarding edges shall have detectable warnings complying with Sections 11B-705.1.1 and 11B-705.1.2.1....
-
11B-247.1.2.1 Platform edges
Platform boarding edges shall have detectable warnings complying with Sections 11B-705.1.1 and 11B-705.1.2.1....
- SafetyStepTD Powerbond Detectable Warning Mat Video
-
Platform Edges: ADA Standard Section 705.2
Detectable warning surfaces at platform boarding edges shall be 24 inches (610 mm) wide and shall extend the full length of the public use areas of the platform....
-
11B-705.1.2.1 Platform edges
Detectable warning surfaces at platform boarding edges shall be 24 inches (610 mm) wide and shall extend the full length of the public use areas of the platform....
-
11B-705.1.2.1 Platform edges
Detectable warning surfaces at platform boarding edges shall be 24 inches (610 mm) wide and shall extend the full length of the public use areas of the platform....
- Armor-Tile Tactile Systems Surface Applied Systems
- Detectable Warning Systems, Inc. AlertCast® Detectable Warning Installation Video
-
11B-705.1.2.7 Track crossings
Detectable warnings at track crossings shall be 36 inches (914 mm) in the direction of pedestrian travel and extend the full width of the circulation path....
-
11B-705.1.2.7 Track crossings
Detectable warnings at track crossings shall be 36 inches (914 mm) in the direction of pedestrian travel and extend the full width of the circulation path....
-
11B-705.1.2.2 Curb ramps
Detectable warnings at curb ramps shall extend 36 inches (914 mm) in the direction of travel....