Doors to Hazardous Areas (Reserved) [4.29.3] and Stairs (Reserved) [4.29.4] In the absence of a clear consensus on the need or specification for detectable warnings at doors and stairs...
Search Results "Detectable Directional Texture"
-
Doors to Hazardous Areas (Reserved) [4.29.3] and Stairs (Reserved) [4.29.4]
-
3.3 Guidance on the Visual Properties of Detectable Warnings
On dark sidewalks (e.g. asphalt) use light colored detectable warnings with a high reflectance fact or to provide light-on-dark contrast rather than using darker detectable warnings to provide...
-
Direct Access Entrances from Parking Structures
Direct Access Entrances from Parking Structures....
- Detectable Warning Systems, Inc. AlertTile® Detectable Warning Installation Video
-
Detectable Warning Surfaces on Boarding Platforms Used by Buses and Rail Vehicles, and Boarding and Alighting Areas Used by Rail Vehicles (Section-by-Section Analysis)
Detectable Warning Surfaces on Boarding Platforms Used by Buses and Rail Vehicles, and Boarding and Alighting Areas Used by Rail Vehicles (Section-by-Section Analysis) The 1991 ADAAG...
-
11B-705.1.1.2 Dome spacing
Truncated domes in a detectable warning surface shall have a center-to-center spacing of 2.3 inches (58 mm) minimum and 2.4 inches (61 mm) maximum, and a base-to-base spacing of 0.65 inch...
-
TACTILE WARNING
A standardized surface texture applied to or built into walking surfaces or other elements to warn visually impaired people of hazards in the path of travel....
-
Audible Signals: ADA Standard Section 407.2.2.3
Section 407.2.2.3 covers the current ADA Standards for elevator audible signals.
-
11B-705.1.1.2 Dome spacing
Truncated domes in a detectable warning surface shall have a center-to-center spacing of 2.3 inches (58 mm) minimum and 2.4 inches (61 mm) maximum, and a base-to-base spacing of 0.65 inch...
-
11B-705.1.1.2 Dome spacing
Truncated domes in a detectable warning surface shall have a center-to-center spacing of 2.3 inches (58 mm) minimum and 2.4 inches (61 mm) maximum, and a base-to-base spacing of 0.65 inch...
-
11B-247.1.2.1 Platform edges
Platform boarding edges shall have detectable warnings complying with Sections 11B-705.1.1 and 11B-705.1.2.1....
-
11B-247.1.2.1 Platform edges
Platform boarding edges shall have detectable warnings complying with Sections 11B-705.1.1 and 11B-705.1.2.1....
-
Platform Edges: ADA Standard Section 705.2
Detectable warning surfaces at platform boarding edges shall be 24 inches (610 mm) wide and shall extend the full length of the public use areas of the platform....
-
11B-705.1.2.1 Platform edges
Detectable warning surfaces at platform boarding edges shall be 24 inches (610 mm) wide and shall extend the full length of the public use areas of the platform....
-
11B-705.1.2.1 Platform edges
Detectable warning surfaces at platform boarding edges shall be 24 inches (610 mm) wide and shall extend the full length of the public use areas of the platform....
-
11B-705.1.2.7 Track crossings
Detectable warnings at track crossings shall be 36 inches (914 mm) in the direction of pedestrian travel and extend the full width of the circulation path....
-
11B-705.1.2.7 Track crossings
Detectable warnings at track crossings shall be 36 inches (914 mm) in the direction of pedestrian travel and extend the full width of the circulation path....
-
Contrast
Detectable warnings are required to contrast visually from adjacent walking surfaces, either light-on dark or dark-on-light....
-
11B-705.1.2.2 Curb ramps
Detectable warnings at curb ramps shall extend 36 inches (914 mm) in the direction of travel....
-
11B-705.1.2.2 Curb ramps
Detectable warnings at curb ramps shall extend 36 inches (914 mm) in the direction of travel....
- Armor-Tile Tactile Systems Surface Applied Systems
-
11B-705.1.2.7 Track crossings
Detectable warnings at track crossings shall be 36 inches (914 mm) in the direction of pedestrian travel and extend the full width of the circulation path....
- Takeform Fusion Signage Floor Directional Type B