A4.30 Signage
-
A4.30.4 Raised and Brailled Characters and Pictorial Symbol Signs (Pictograms)
A4.30.4 Raised and Brailled Characters and Pictorial Symbol Signs (Pictograms). The standard dimensions for literary Braille are as follows: Dot diameter .059...
-
A4.30.5 Finish and Contrast
An eggshell finish (11 to 19 degree gloss on 60 degree glossimeter) is recommended. Research indicates that signs are more legible for persons with low vision when characters...
-
216 Signs
1991 Standards for Accessible Design 2010 Standards for Accessible Design What’s New/Different 4.1.3(16)(a) Signs...
-
Attachment I
Although 3 parking spaces are designated for persons with disabilities at the rear of Municipal Hall, none is “van-accessible.” ...
-
Attachment J
as “van accessible” and the vertical signs on all designated spaces are mounted too low. ...
-
Floor Naming and Numbering
This is a little abstract one, but if you look at those elevator buttons, whether you’re in a building in San Francisco and you come in on the east side of the building and it’s...
-
68.101(c)(5)(E) Signage at toilet rooms or bathrooms
(E) Signage at toilet rooms or bathrooms shall comply with TAS 703. Toilet rooms or bathrooms serving the leased area which are not accessible shall be provided with signage...
-
5d.
5d. Are raised letters and Braille characters used to identify each floor button and each control? [ADA Stds 4.10.12] Yes _____ No _____
-
TACTILE SIGN
TACTILE SIGN. A sign containing raised characters and/or symbols and accompanying Braille.
-
1008.1.9.7, Item 5.1
5.1 A tactile sign shall also be provided in Braille and raised characters, which complies with Chapter 11B, Sections 11B-703.1, 11B-703.2, 11B-703.3 and 11B-703.5.
-
11B-216 SIGNS
-
11B-216.1 General
Building directories, menus, seat and row designations in assembly areas, occupant names, building addresses, and company names and logos shall not be required to comply with Section 11B...
-
11B-216.4.1 Exit doors
Signs required by Chapter 10, Section 1011.4 at doors to exit passageways, exit discharge, and exit stairways shall comply with Sections 11B-703.1 _|Signs; General|_ 11B-703.2...
-
11B-703 SIGNS
-
11B-703.1 General
Signs shall comply with Section 11B-703. Where both visual and tactile characters are required, either one sign with both visual and tactile characters, or two separate signs, one...
-
11B-703.1.1 Plan review and inspection
Signs as specified in Section 11B-703, or in other sections of this code, when included in the construction of new buildings or facilities, or when included, altered or replaced due...
-
11B-703.1.1.2 Inspection
Signs and identification devices shall be field inspected after installation and approved by the enforcing agency prior to the issuance of a final certificate of occupancy per...
-
11B-703.4 Installation height and location
Signs with tactile characters shall comply with Section 11B-703.4.
-
11B-703.4.1 Height above finish floor or ground
Tactile characters on signs shall be located 48 inches (1219 mm) minimum above the finish floor or ground surface, measured from the baseline of the lowest Braille cells and 60...
-
11B-703.4.2 Location
Where a tactile sign is provided at a door, the sign shall be located alongside the door at the latch side. Where a tactile sign is provided at double doors with one active leaf, the...
-
11B-703.5 Visual characters
Visual characters shall comply with Section 11B-703.5. Exception: Where visual characters comply with Section 11B-703.2 _|Signs; Raised Characters|_ and are accompanied by Braille...
-
11B-703.5.1 Finish and contrast
Characters and their background shall have a non-glare finish. Characters shall contrast with their background with either light characters on a dark background or dark characters on...
-
11B-703.5.2 Case
Characters shall be uppercase or lowercase or a combination of both.