Accessible water closets shall comply with 4.16. For water closets in accessible dwelling units, see 4.34.5.2....
Search Results "Closet Door"
-
4.16.1 GENERAL
-
Automated Revolving Doors
Automated Revolving Doors Automated revolving doors, if large enough, may be usable by many people who use wheelchairs although ADAAG requires that a revolving door not be the only means...
-
404.2.9 Door and Gate Opening Force
The force for pushing or pulling open a door or gate other than fire doors shall be as follows: 1. Interior hinged doors and gates: 5 pounds (22.2 N) maximum. 2....
-
404.2.9 Door and Gate Opening Force
The force for pushing or pulling open a door or gate other than fire doors shall be as follows: 1. Interior hinged doors and gates: 5 pounds (22.2 N) maximum. 2....
-
Water Closet Location and Rear Grab Bar
Water Closet Location and Rear Grab Bar....
-
11B-404.3.2 Maneuvering clearance
Clearances at power-assisted doors and gates shall comply with Section 11B-404.2.4....
-
11B-404.3.2 Maneuvering clearance
Clearances at power-assisted doors and gates shall comply with Section 11B-404.2.4....
-
11B-604.8.1.1.2 Maneuvering space with side-opening door
In a wheelchair accessible compartment with a door located in the side wall or partition, either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide and 60 inches (1524 mm) deep...
-
11B-604.8.1.1.2 Maneuvering space with side-opening door
In a wheelchair accessible compartment with a door located in the side wall or partition, either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide and 60 inches (1524 mm) deep...
-
Maneuvering Clearance: ADA Standard Section 404.3.2
Section 404.3.2 covers the current ADA Standards for maneuvering clearance at automatic and power-assisted doors and gates.
-
Height: ADA Standard Section 604.9.3
Section 604.9.3 covers the current ADA Standards for the height of children's use water closets.
-
11B-604.9.3 Height
The height of water closets shall be 11 inches (279 mm) minimum and 17 inches (432 mm) maximum measured to the top of the seat....
-
11B-604.9.3 Height
The height of water closets shall be 11 inches (279 mm) minimum and 17 inches (432 mm) maximum measured to the top of the seat....
-
407.3.5 Door Delay
Elevator doors shall remain fully open in response to a car call for 3 seconds minimum....
-
407.3.5 Door Delay
Elevator doors shall remain fully open in response to a car call for 3 seconds minimum....
-
11B-404.3.1 Clear width
The minimum clear width for automatic door systems in a doorway shall provide a clear, unobstructed opening of 32 inches (813 mm) with one leaf positioned at an angle of 90 degrees from...
-
11B-404.3.1 Clear width
The minimum clear width for automatic door systems in a doorway shall provide a clear, unobstructed opening of 32 inches (813 mm) with one leaf positioned at an angle of 90 degrees from...
-
11B-206.5.2 Rooms and spaces
Within a building or facility, every door, doorway or gate serving rooms and spaces complying with this chapter shall comply with Section 11B-404....
-
11B-206.5.2 Rooms and spaces
Within a building or facility, every door, doorway or gate serving rooms and spaces complying with this chapter shall comply with Section 11B-404....
-
11B-604.2 Location
The water closet shall be positioned with a wall or partition to the rear and to one side....
-
11B-604.2 Location
The water closet shall be positioned with a wall or partition to the rear and to one side....
-
11B-407.3.5 Door delay
Elevator doors shall remain fully open in response to a car call for 5 seconds minimum. [2010 ADAS] 407.3.5 Door Delay. ...
-
11B-407.3.5 Door delay
Elevator doors shall remain fully open in response to a car call for 5 seconds minimum. [2010 ADAS] 407.3.5 Door Delay....
-
11B-407.3.5 Door delay
Elevator doors shall remain fully open in response to a car call for 5 seconds minimum. [2010 ADA Standards] 407.3.5 Door Delay....