Characters shall be ½ inch (12.7 mm) high minimum....
Search Results "Character Height (Raised)"
-
11B-407.4.8.1.1 Size
-
A4.30.2 Character Proportion
The legibility of printed characters is a function of the viewing distance, character height, the ratio of the stroke width to the height of the character, the contrast of color between...
-
A4.30.2 CHARACTER PROPORTION
The legibility of printed characters is a function of the viewing distance, character height, the ratio of the stroke width to the height of the character, the contrast of color between...
-
11B-216.2 Designations
Interior and exterior signs identifying permanent rooms and spaces shall comply with Sections 11B-703.1 _|Signs; General|_ 11B-703.2 _|Signs; Raised Characters|_, 11B-703.3 _|Braille|_,...
-
§ 38.55(b)
(b) Characters on signs required by paragraph (a) of this section shall have a width-to-height ratio between 3:5 and 1:1 and a stroke width-to-height ratio between 1:5 and 1:10, with a minimum...
-
Height: ADA Standard Section 804.3.2
EXCEPTION: A counter that is adjustable to provide a kitchen work surface at variable heights, 29 inches (735 mm) minimum and 36 inches (915 mm) maximum, shall be permitted....
-
1008.1.9.7, Item 5.1
5.1 A tactile sign shall also be provided in Braille and raised characters, which complies with Chapter 11B, Sections 11B-703.1, 11B-703.2, 11B-703.3 and 11B-703.5....
-
Transfer Height: ADA Standard Section 1002.5.2
The height of amusement ride seats designed for transfer shall be 14 inches (355 mm) minimum and 24 inches (610 mm) maximum measured from the surface of the load and unload area....
-
Height: ADA Standard Section 902.3
The tops of dining surfaces and work surfaces shall be 28 inches (710 mm) minimum and 34 inches (865 mm) maximum above the finish floor or ground.
-
§ 38.105(b)
(b) Characters on signs required by paragraph (a) shall have a width-to-height ratio between 3:5 and 1:1 and a stroke width-to-height ratio between 1:5 and 1:10, with a minimum character...
-
Line Spacing: ADA Standard Section 703.5.9
Spacing between the baselines of separate lines of characters within a message shall be 135 percent minimum and 170 percent maximum of the character height....
-
11B-703.5.9 Line spacing
Spacing between the baselines of separate lines of characters within a message shall be 135 percent minimum and 170 percent maximum of the character height....
-
11B-703.5.9 Line spacing
Spacing between the baselines of separate lines of characters within a message shall be 135 percent minimum and 170 percent maximum of the character height....
-
§ 38.27(c)
(c) Characters on signs required by paragraphs (a) and (b) of this section shall have a width-to-height ratio between 3:5 and 1:1 and a stroke width-to-height ratio between 1:5 and 1:10,...
-
11B-216.4.4 Delayed egress locks
Signs required by Chapter 10, Section 1010.1.9.7, Item 6.4 at doors with delayed egress locks shall comply with Sections 11B-703.1, 11B-703.2, 11B-703.3, and 11B-703.5.
-
11B-216.2 Designations
at the door to the space that they serve, but this is inferable from the fact that the requirement for braille is contained within 11B-703.2, as are the requirements pertaining to the height...
-
A4.30.4 Raised and Brailled Characters and Pictorial Symbol Signs (Pictograms)
A4.30.4 Raised and Brailled Characters and Pictorial Symbol Signs (Pictograms)....
-
11B-903.5 Height
The top of the bench seat surface shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum above the finish floor or ground.
-
11B-903.5 Height
The top of the bench seat surface shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum above the finish floor or ground.
-
Exit Doors: ADA Standard Section 216.4.1
Section 216.4.1 covers scoping requirements in the current ADA Standards for signs at exit doors.
-
11B-216.4.1 Exit doors
Signs required by Chapter 10, Section 1013.4 at doors to exit passageways, exit discharge, and exit stairways shall comply with Sections 11B-703.1, 11B-703.2, 11B-703.3, and...
-
11B-216.4.1 Exit doors
Signs required by Chapter 10, Section 1013.4 at doors to exit passageways, exit discharge, and exit stairways shall comply with Sections 11B-703.1, 11B-703.2, 11B-703.3, and...
-
11B-411.2.1.2.4.2 Size
Elevator assignment characters shall be 1 inch high (25 mm) minimum....
-
11B-411.2.1.2.4.2 Size
Elevator assignment characters shall be 1 inch high (25 mm) minimum....