Search Results "Bedside Clearance"
Commonly Searched Documents
- Figure 404.2.4.1(h) Maneuvering Clearances at Manual Swinging Doors and Gates: Latch Approach, Pull Side – Drawing from the U.S. Access Board
- Figure 404.2.4.1(j) Maneuvering Clearances at Manual Swinging Doors and Gates: Latch Approach, Push Side – Drawing from the U.S. Access Board
- Figure 404.2.4.1(d) Maneuvering Clearances at Manual Swinging Doors and Gates: Hinge Approach, Pull Side – Drawing from the U.S. Access Board
- Figure 404.2.4.1(i) Maneuvering Clearances at Manual Swinging Doors and Gates: Latch Approach, Pull Side with Closer – Drawing from the U.S. Access Board
-
A4.34.6.1 CLEARANCE
The minimum clearances provide satisfactory maneuvering spaces for wheelchairs only if cabinets are removed at the sink....
-
M303.2.4 Knee and Toe Clearance
Wheelchair spaces shall include knee and toe clearance complying with M303.2.4....
- Figure 404.2.4.1(g) Maneuvering Clearances at Manual Swinging Doors and Gates: Hinge Approach, Push Side with Closer and Latch – Drawing from the U.S. Access Board
-
Minimum Required Depth: ADA Standard Section 306.2.3
Section 306.2.3 covers the current ADA Standards for the minimum required depth for toe clearance.
-
M303.2.4 Equipment Clearances
Where wheelchair spaces are entered from the rear and includes space beneath components, wheelchair spaces shall include knee and toe clearances complying with M303.2.4.1 for breast platforms...
-
R402.4 Reduced Vertical Clearance
R402.4 Reduced Vertical Clearance. Guardrails or other barriers to pedestrian travel shall be provided where the vertical clearance is less than 2 m (6.7 ft) high....
-
Can handrails or other elements overlap door maneuvering clearances?
No, door maneuvering clearances must be free of any overlapping objects, even those providing knee and toe clearance, which can interfere with maneuvering at doors and doorways....
- SafePath EntryLevel™ Landings
-
3.3.6 Knee Clearance Height, minimum
3.3.6 Knee Clearance Height, minimum Knee clearance heights for the four sets of standards range from 650 mm (25.6 in.) (Australia) to 700 mm (27.6 in.) (U.K.) (Figure 3‒6)....
-
3.3.7 Toe Clearance Height, minimum
3.3.7 Toe Clearance Height, minimum There is relatively large disparity between the standards for toe clearance height, with the U.S. having the lowest (230 mm or 9 in.), followed by...
-
3.3.8 Knee Clearance Depth, minimum
3.3.8 Knee Clearance Depth, minimum Knee clearance depths for the four sets of standards range from 200 mm (8 in.) in Canada to 280 mm (11 in.) in the U.S. (Figure 3‒8)....
-
Forward Approach: ADA Standard Section 904.4.2
A portion of the counter surface that is 30 inches (760 mm) long minimum and 36 inches (915 mm) high maximum shall be provided. Knee and toe space complying with 306 shall be...
-
Obstructed High Reach: ADA Standard Section 308.2.2
Section 308.2.2 covers the current ADA Standards for obstructed high reach.
-
11B-904.4.2 Forward approach
A portion of the counter surface that is 36 inches (914 mm) long minimum and 34 inches (864 mm) high maximum shall be provided. Knee and toe space complying with Section 11B-306...
-
3.3.9 Toe Clearance Depth, minimum
3.3.9 Toe Clearance Depth, minimum Toe clearance depths for the standards range from 150 mm (6 in.) in the U.S. to 230 mm (9 in.) in Canada (Figure 3‒9)....
-
a. Knee and Toe Clearance
The proposed rule recommended a knee and toe clearance depth for breast platforms of 25 inches. There were no comments received on this requirement....
-
11B-411.4.3 Platform to hoistway clearance
Platform to hoistway clearance shall comply with Section 11B-407.4.3....
-
11B-411.4.3 Platform to hoistway clearance
Platform to hoistway clearance shall comply with Section 11B-407.4.3....
-
11B-411.4.3 Platform to hoistway clearance
Platform to hoistway clearance shall comply with Section 11B-407.4.3....
-
11B-405.7.5 Doorways
Where doorways are located adjacent to a ramp landing, maneuvering clearances required by Sections 11B-404.2.4 and 11B-404.3.2 shall be permitted to overlap the required landing area....