Each transfer step shall be 8 inches (203 mm) high maximum....
Search Results "Assisted Transfer"
Commonly Searched Documents
-
11B-1008.3.2.2 Height
-
Clear Deck Space
wheelchair can turn around and maneuver into transfer position....
-
Transfer Device
Transfer Device. Equipment designed to facilitate the transfer of a person from a wheelchair or other mobility aid to and from an amusement ride seat....
-
TRANSFER DEVICE
TRANSFER DEVICE. [DSA-AC] Equipment designed to facilitate the transfer of a person from a wheelchair or other mobility aid to and from an amusement ride seat....
-
Size: ADA Standard Section 1008.3.1.1
Transfer platforms shall have level surfaces 14 inches (355 mm) deep minimum and 24 inches (610 mm) wide minimum....
-
Size: ADA Standard Section 1008.3.2.1
Transfer steps shall have level surfaces 14 inches (355 mm) deep minimum and 24 inches (610 mm) wide minimum....
-
11B-1008.3.1.1 Size
Transfer platforms shall have level surfaces 14 inches (356 mm) deep minimum and 24 inches (610 mm) wide minimum....
-
11B-1008.3.2.1 Size
Transfer steps shall have level surfaces 14 inches (356 mm) deep minimum and 24 inches (610 mm) wide minimum....
-
Transfer Access [1014.2.1]
To provide transfer access at the entrance to a camp shelter, a clear ground space at least 36 by 48 inches positioned for a parallel approach must be provided along the open side of the...
-
11B-1009.5.4 Transfer steps
Transfer step height shall be 8 inches (203 mm) maximum. The surface of the bottom tread shall extend to a water depth of 18 inches (457 mm) minimum below the stationary water level....
-
11B-703.7.2.4 Assistive listening systems
Assistive listening systems shall be identified by the International Symbol of Access for Hearing Loss complying with Figure 11B-703.7.2.4....
-
Maneuvering Clearance: ADA Standard Section 404.3.2
Section 404.3.2 covers the current ADA Standards for maneuvering clearance at automatic and power-assisted doors and gates.
-
§382.81 For which passengers must carriers make seating accommodations?
As a carrier, you must provide the following seating accommodations to the following passengers on request, if the passenger self-identifies to you as having a disability specified...
-
382.81 For which passengers must carriers make seating accommodations?
382.81 For which passengers must carriers make seating accommodations? ETA Editor's Note This section has no content in the original document.
-
Height: ADA Standard Section 1008.3.1.2
The height of transfer platforms shall be 11 inches (280 mm) minimum and 18 inches (455 mm) maximum measured to the top of the surface from the ground or floor surface....
-
11B-1008.3.1.2 Height
The height of transfer platforms shall be 11 inches (279 mm) minimum and 18 inches (457 mm) maximum measured to the top of the surface from the ground or floor surface....
-
Boarding Assistance
Boarding Assistance When communicating to carrier personnel about your need for boarding assistance, be as specific as possible about the type or level of boarding assistance you require...
-
‘‘Assistant Attorney General.’’
‘‘Assistant Attorney General.’’ The term ‘‘Assistant Attorney General’’ refers to the Assistant Attorney General of the Civil Rights Division of the Department of Justice....
-
1. Transfer Supports
The MDE NPRM proposed requirements for transfer supports that applied to all transfer surfaces (proposed M305.2)....
-
11B-1002.5.3 Transfer entry
Where openings are provided for transfer to amusement ride seats, the openings shall provide clearance for transfer from a wheelchair or mobility aid to the amusement ride seat....
-
11B-1002.5.3 Transfer entry
Where openings are provided for transfer to amusement ride seats, the openings shall provide clearance for transfer from a wheelchair or mobility aid to the amusement ride seat....
-
11B-1002.5.3 Transfer entry
Where openings are provided for transfer to amusement ride seats, the openings shall provide clearance for transfer from a wheelchair or mobility aid to the amusement ride seat....
-
1014.2.1 Transfer Access
Where transfer access is provided, this section requires a clear ground space 36 inches minimum by 48 inches minimum positioned for a parallel approach to be provided at the entrance to...
-
Using Patient Lifts