Section 206.5.1 covers scoping requirements in the most current ADA Standards for the use of platform lifts due to existing site constraints.
Search Results "Ramp Width"
-
Existing Site Constraints: ADA Standard Section 206.7.5
-
408.4.1 Car Dimensions and Doors
Elevator cars shall provide a clear width 42 inches (1065 mm) minimum and a clear depth 54 inches (1370 mm) minimum....
-
11B-206.7.5 Existing site constraints
Platform lifts shall be permitted where existing exterior site constraints make use of a ramp or elevator infeasible. Advisory 11B-206.7.5 Existing site constraints....
-
11B-206.2.3.2 Distance to Elevators
new construction of buildings where elevators are required by Section 11B-206.2.3, and which exceed 10,000 square feet (929 m2) on any floor, an accessible means of vertical access via ramp...
-
11B-206.7.5 Existing site constraints
Platform lifts shall be permitted where existing exterior site constraints make use of a ramp or elevator infeasible. Advisory 11B-206.7.5 Existing site constraints....
-
11B-206.2.3.2 Distance to Elevators
new construction of buildings where elevators are required by Section 11B-206.2.3, and which exceed 10,000 square feet (929 m2) on any floor, an accessible means of vertical access via ramp...
-
1013.4 Raised character and braille exit signs
Each exit door that is required to comply with Section 1013.1, and that leads directly to a grade-level exterior exit by means of a stairway or ramp shall be identified by a tactile exit...
-
Ground Level Play Components: ADA Standard Section 240.2.1
Section 240.2.1 covers scoping requirements in the current ADA Standards for ground level play components.
-
11B-240.2.1 Ground level play components
A ramp or transfer system to the top of the slide is not required. Where a sand box is provided, an accessible route must connect to the border of the sand box....
-
11B-240.2.1 Ground level play components
A ramp or transfer system to the top of the slide is not required. Where a sand box is provided, an accessible route must connect to the border of the sand box....
-
Expert Report of Jeromy G. Murphy, American Construction Investigations, LTD (August 6, 2018)
Building Entrance: One side of the double leaf doors at the designated accessible entrance does not provide at least 32 inches clear passage width when the door is open 90 degrees (1991...
-
11B-403.3 Slope
When the running slope of a walking surface exceeds 5%, it must comply with the accessibility requirements for ramps....
-
Accessible Routes
The accessible route must comply with ADAAG provisions for the location, width (minimum of 36 inches), passing space, head room, surface, slope (maximum of 1:12 or 8.33%), changes in level...
-
11B-403.3 Slope
When the running slope of a walking surface exceeds 5%, it must comply with the accessibility requirements for ramps....
-
Transfer Surface Size – M302.2.2 Seated Position
The Subcommittee discussed the width and agreed on a 21 inch minimum width based on anthropometric data and industry human factors experience....
-
408.4.1 Car Dimensions and Doors
Elevator cars shall provide a clear width 42 inches (1065 mm) minimum and a clear depth 54 inches (1370 mm) minimum....
-
Detectable Warning Surfaces at Shared Use Path Intersections
facilities in the public right-of-way would require the use of detectable warning surfaces to indicate the boundary between a pedestrian route and a vehicular route where there is a curb ramp...
-
11B-812.1 General
Exception: Where vehicle spaces or access aisles are not adjacent to another vehicle space, access aisle, or parking space, measurements shall be permitted to include the full width of the...
-
11B-812.1 General
Exception: Where vehicle spaces or access aisles are not adjacent to another vehicle space, access aisle, or parking space, measurements shall be permitted to include the full width of the...
-
2.2.2 Structural Anthropometry (i.e. Body and WhMD Dimensions)
Lateral most point, left (arm, leg, WhMD or accessory) Used to measure Occupied Width....
- Detectable Warning Systems, Inc. AlertTile® Detectable Warning
-
408.4.1 Car Dimensions and Doors
Elevator cars shall provide a clear width 42 inches (1065 mm) minimum and a clear depth 54 inches (1370 mm) minimum....
-
11B-812.5.3 Relationship to accessible routes
Vehicle spaces and access aisles shall be designed so that when the vehicle space is occupied the required clear width of adjacent accessible routes is not obstructed....
-
11B-812.5.3 Relationship to accessible routes
Vehicle spaces and access aisles shall be designed so that when the vehicle space is occupied the required clear width of adjacent accessible routes is not obstructed....