The height of the lift seat shall be designed to allow a stop at 16 inches (405 mm) minimum to 19 inches (485 mm) maximum measured from the deck to the top of the seat surface when in the...
Search Results "Maximum Dimension"
-
1009.2.4 Seat Height
-
11B-608.6 Shower spray unit and water
Corrects prior drafting error by limiting the types of facilities that are allowed to use the vandalism prone area exception and requiring one of the two shower heads to be a maximum of...
-
308.2.1 Unobstructed
Where a forward reach is unobstructed, the high forward reach shall be 48 inches (1220 mm) maximum and the low forward reach shall be 15 inches (380 mm) minimum above the finish floor or...
-
803.5 Coat Hooks and Shelves
Shelves shall be 40 inches (1015 mm) minimum and 48 inches (1220 mm) maximum above the finish floor or ground....
-
7.3(2)
(2) Clear aisle width for accessible check-out aisles shall comply with 4.2.1 and maximum adjoining counter height shall not exceed 38 in (965 mm) above the finish floor....
-
§ 37.169(e)
(e) In any case in which a public entity denies a request for a reasonable modification, the entity shall take, to the maximum extent possible, any other actions (that would not result in...
-
11B-604.8.3 Coat hooks and shelves
Shelves shall be located 40 inches (1016 mm) minimum and 48 inches (1219 mm) maximum above the finish floor....
-
§ 37.169(e)
(e) In any case in which a public entity denies a request for a reasonable modification, the entity shall take, to the maximum extent possible, any other actions (that would not result in...
-
11B-605.2 Height and depth
Urinals shall be the stall-type or the wall-hung type with the rim 17 inches (432 mm) maximum above the finish floor or ground....
- Midmark 641 Barrier-Free® Power Procedures Chair
- Hadrian Inc. Gladiator Athletic Lockers
- AquaTrek2 ADA Wading Pool Ramp
-
Database Development
., 2007; 2010a), as well as generate summary statistics on a number of different body and device dimensions (Paquet & Feathers, 2004)....
- Bridge II Sconce by Hampstead
- Bridge I Sconce by Hampstead
- Geberit Monolith Floor Mounted Toilet with White Glass
-
11B-1009.5.6 Size
Each transfer step shall have a tread clear depth of 14 inches (356 mm) minimum and 17 inches (432 mm) maximum and shall have a tread clear width of 24 inches (610 mm) minimum....
-
604.8.3 Coat Hooks and Shelves
Shelves shall be located 40 inches (1015 mm) minimum and 48 inches (1220 mm) maximum above the finish floor. [ECTCR UFAS 4.25.3, Fig. 38, 4.23.9, 4.34.5.3(3)]...
-
1009.4.3 Wall Depth and Length
The depth of the transfer wall shall be 12 inches (305 mm) minimum and 16 inches (405 mm) maximum....
-
504.2 Treads and Risers
Risers shall be 4 inches (100 mm) high minimum and 7 inches (180 mm) high maximum. Treads shall be 11 inches (280 mm) deep minimum....
-
803.5 Coat Hooks and Shelves
Shelves shall be 40 inches (1015 mm) minimum and 48 inches (1220 mm) maximum above the finish floor or ground. [ECTCR UFAS 4.25.3, Fig. 38]...
-
5.4.4.2 Transfer Support Distance from Transfer Surface for Imaging Equipment
Supports (transfer or positioning) should be located 1 ½ inches maximum from the transfer surface....
-
R408.2 Treads and Risers
Risers shall be 100 mm (4 in) high minimum and 180 mm (7 in) high maximum. Treads shall be 280 mm (11 in) deep minimum....
-
C1-d
[ADA Standards § 4.3.8] Yes No Note: Level changes between 1/4 inch and 1/2 inch should be beveled (sloped) at 1:2 maximum....