Maximum Slope at Ground Level
-
Dumpster Enclosure
Just as an FYI, Texas has a Technical Memorandum that briefly addresses dumpster enclosures. It is TM 2013-21.
-
Universal Design for Health Care Facilities
Universal Design for Health Care Facilities: Addressing Safety, Access to Care for a Diverse Patient Population Environment of Care® News, January 2009, Volume 12, Issue 1 Copyright...
-
Surface and Size [§305.2 and §305.3]
They must be free of level changes and not slope more than 1:48. The minimum size (30” by 48”) applies whether the space is positioned for forward or side approaches....
-
808.2 Turning Space
Where provided, areas that are raised or depressed and accessed by ramps or platform lifts with entry ramps shall provide unobstructed turning space complying with 304....
-
808.2 Turning Space
Where provided, areas that are raised or depressed and accessed by ramps or platform lifts with entry ramps shall provide unobstructed turning space complying with 304....
-
Rough Form and Foundation Inspection
ROUGH FORM AND FOUNDATION INSPECTION Verify building form elevations are set relative to site features (accessible routes, accessible parking, common and public use areas...
-
Rough Form and Foundation Inspection
ROUGH FORM AND FOUNDATION INSPECTION Verify building form elevations are set relative to site features (accessible routes, accessible parking, common and public use areas...
- Implementing the Affordable Care Act (ACA): A Roadmap for People with Disabilities
-
M305.3.1.1 Horizontal Position
The length of gripping surfaces on horizontal standing supports shall be 4 inches (100 mm) minimum except for diagnostic equipment containing a wheelchair space which shall comply...
-
M303.3.3.3 Clear Width
The clear width of ramp runs shall be 36 inches (915 mm) minimum.
-
M303.2.4.2 Other Equipment
Wheelchair spaces beneath diagnostic equipment other than breast platforms shall comply with M303.2.4.2.
-
F223.3 Long-Term Care Facilities
In licensed long-term care facilities, at least 50 percent, but no fewer than one, of each type of resident sleeping room shall provide mobility features complying with 805.
-
M302.2.5 Unobstructed Transfer
Each transfer side complying with M302.2.4 shall provide unobstructed access to transfer surfaces. EXCEPTIONS: 1. Obstructions no more than 3 inches (75 mm) deep shall be...
-
M303.3.3.1 Running Slope
Ramp runs shall have a running slope not steeper than 1:12. EXCEPTION: A running slope not steeper than 1:8 shall be permitted for ramp runs with a maximum height of 2 ½ inches...
-
M305.3.2.1 Horizontal Position
The height of the top of the gripping surface on horizontal standing supports shall be 34 inches (865 mm) minimum and 38 inches (965 mm) maximum above the standing surface.
-
M303.3.3.4 Edge Protection
Ramps with drop offs ½ inch (13 mm) or greater shall provide edge protection 2 inches (50 mm) high minimum on each side with a drop off.
-
M303.3.3.5 Handrails
Ramps with a rise greater than 6 inches (150 mm) shall provide handrails on both sides.
-
223.3 Long-Term Care Facilities
In licensed long-term care facilities, at least 50 percent, but no fewer than one, of each type of resident sleeping room shall provide mobility features complying with 805.
-
5.8.1.1 Clear Platform Size Recommendation
5.8.1.1 Clear Platform Size Recommendation The Committee recommends a platform size with a minimum clear width of 32 inches and a minimum clear length of 40 inches. Rationale...
-
5.8.1.1 Clear Platform Size
5.8.1.1 Clear Platform Size. The platform should be a minimum clear width of 32-inches and a minimum clear length of 40-inches.
-
223.3 Long-Term Care Facilities
223.3 Long-Term Care Facilities. In licensed long-term care facilities, at least 50 percent, but no fewer than one, of each type of resident sleeping room shall provide mobility...
-
Master Bedroom
Cross ventilation for fresh air while sleeping. Touch controls on all cabinets and doors (no knobs) Touch controls on metal lamps (master bedroom) Touch...
-
M303.3.3.5 Handrails
Ramps with a rise greater than 6 inches (150 mm) shall provide handrails on each side.