Search Results "Assisted Transfer"
Commonly Searched Documents
-
Adjustable gap protocol
-
3.3.2 Experienced Clinicians
Access Board staff asked these clinicians to comment on topics primarily related to transferring patients and the implications for recommendations relating to transfer surfaces....
-
M301.4 Lift Compatibility
Note: in some circumstances such as in-room MR, the option for a room layout for gurney transfer would be appropriate....
-
Participants
The target sample populations were individuals who live in the community and use a wheeled mobility device, as well as having the ability to transfer independently and represent a broad...
-
D. Beds in accessible guest rooms and sleeping rooms
In recent years, hotels have provided higher beds, using thicker mattresses that make it difficult or impossible for many individuals who use wheelchairs to transfer onto the beds....
-
2. Types of Telephone Emergency Services Covered
It transfers calls to secondary PSAPs, such as fire or emergency medical services. In those transfer situations, PSAPs must understand how to correctly transfer TTY calls....
-
M302.3.2 Armrests
Armrests on transfer sides are not permitted to obstruct access to the transfer surface. See M302.2.3 Exception....
-
Positioning Supports Considered
[to] increase safety and assist patients in transferring on and off, positioning or repositioning their bodies, and maintaining static position.” See ANSI/AAMI HE 75, section 16.4.6....
-
11B-502.4 Floor or ground surfaces
Access aisles are required to be nearly level in all directions to provide a surface for wheelchair transfer to and from vehicles. The exception allows sufficient slope for drainage....
-
1009 Swimming Pools, Wading Pools, and Spas
Specifications are provided for various means of providing pool access, including pool lifts, sloped entries, transfer walls, transfer systems, and stairs....
-
Armrests (M302.3.2)
HE75 which recommends that “[f]or support surfaces that require the patient to assume a seated position, armrests should be provided to enhance patient comfort, stability, and ease of transfer...
-
Expert opinion on current literature
The aspects of setup that experts felt were addressed to some degree included vertical transfer distance, transferring across a gap and position of the mobility device relative to target...
-
ALIGNMENT OF 19-INCH RECOMMENDATION WITH ACCESS BOARD PROPOSED RULEMAKING
In its proposed rule, the Access Board proposed that the “height of the transfer surface during patient transfer shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum measured...
- Guldmann GLS5 Active lifter
-
Accessible Rides
Accessible Rides Each newly constructed or newly designed amusement ride must provide at least one wheelchair space, or at least one ride seat designed for transfer, or a transfer device...
-
Summary
This analysis focuses only on the adequacy of the proposed transfer surface dimensions as a static seating surface – i.e., no measurements of transfers were recorded....
-
2.3 Implications of MDE Accessibility for Clinical Staff
2.3 Implications of MDE Accessibility for Clinical Staff Health care personnel face risks of injuries from transferring, positioning, or otherwise physically assisting patients in health...
-
25. No Assignment of Claims
No Assignment of Claims Each of the Plaintiffs, for themselves and as representatives of the Settlement Class, represent and warrant that they have not transferred or otherwise assigned...
-
Background
Most programs and activities of State and local governments are recipients of Federal financial assistance from one or more Federal funding agencies and, therefore, are already covered by...
-
Subjects
Subjects The target sample required wheeled mobility device users who lived in the community and were able to transfer independently (with or without a transfer board) and who represent...
-
Side guard protocol
Of the 60 subjects that were able to transfer to a higher level than their own WMD, 98% (59/60), CI[91%,99%] were able to transfer to height of 22” (55.9cm) (Figure 12 and Table 8)....
-
Adjustable gap protocol
One hundred and fourteen (114) subjects were tested under this protocol and six could not transfer with a gap of any size added between their WMD and the platform in the configuration shown...
-
Bathrooms
Some rooms in larger facilities must have a combination roll-in/ transfer shower....
-
M301 Diagnostic Equipment Used by Patients in Supine, Prone, or Side-Lying Position; M302 Diagnostic Equipment Used by Patients in Seated Position
The purpose of these sections is to facilitate independent transfer onto and off of diagnostic equipment by patients with disabilities, including those who use mobility devices or aids,...