EXCEPTION: Braille provided on elevator car controls shall be separated 3/16 inch (4.8 mm) minimum and shall be located either directly below or adjacent to the corresponding raised characters...
Search Results "Elevator Keypad"
Commonly Searched Documents
-
703.3.2 Position
-
Egress [4.1.3(9), 4.3.10]
In multi-story buildings where stories are located above or below the level of exit discharge, evacuation elevators can be used as part of an accessible means of egress....
-
11B-703.5.6 Height from finish floor or ground
Visual characters indicating elevator car controls shall not be required to comply with Section 11B-703.5.6. 2....
-
11B-407.4.9 Emergency communication
Emergency two-way communication systems between the elevator and a point outside the hoistway shall comply with ASME A17.1. [2010 ADAS] 407.4.9 Emergency Communication....
-
11B-407.4.9 Emergency communication
Emergency two-way communication systems between the elevator and a point outside the hoistway shall comply with ASME A17.1. [2010 ADA Standards] 407.4.9 Emergency Communication....
-
1010.1.6 Thresholds
In adaptable or accessible dwelling units, where Exception 5 to Section 1010.1.5 permits a 4-inch (102 mm) elevation change at the door, the threshold height on the exterior side of the...
-
11B-1003.2.1 Boat slips
The vertical distance is 10 feet (3050 mm) between the elevation where the gangway departs the landside connection and the elevation of the pier surface at the lowest water level....
-
11B-1003.2.1 Boat slips
The vertical distance is 10 feet (3050 mm) between the elevation where the gangway departs the landside connection and the elevation of the pier surface at the lowest water level....
- PEMKO 1 3/8" Floor Plate/Safety Tread No. 195
-
703.3.2 Position
EXCEPTION: Braille provided on elevator car controls shall be separated 3/16 inch (4.8 mm) minimum and shall be located either directly below or adjacent to the corresponding raised characters...
-
703.3.2 Position
EXCEPTION: Braille provided on elevator car controls shall be separated 3/16 inch (4.8 mm) minimum and shall be located either directly below or adjacent to the corresponding raised characters...
-
6.7.1 Running Slope (Grade)
Elevated dune crossings shall not be required to comply with the resting interval requirements in 6.7.1....
-
Escalators
Escalators must have a clear width of at least 32” and meet specific provisions in the ASME A17.1 Safety Code for Elevators and Escalators....
- Door King Inc. 1520/1524 Stand Alone Card Readers
- Courtesy Direct Dial Handset Phones
- 1100KL EHR Digital Platform Scale with Extra Wide Handrails and Digital Height Rod
- 1100KL HR Digital Platform Scale Extra Wide Handrail with Mechanical Height Rod
- 1100KL BT Digital Platform Scale Extra Wide Handrails and Built-in Pelstar® Wireless Technology
- Community Resources for Independent Living - Hayward, Fremont, Livermore, Anaheim, CA
-
11B-206.3 Location
Elements such as ramps, elevators, or other circulation devices, fare vending or other ticketing areas, and fare collection areas shall be placed to minimize the distance which wheelchair...
-
11B-703.3.1 Dimensions and capitalization
When dealing with sign manufacturers or elevator companies whose scope of operations extends outside California, extra diligence is necessary to ensure that CBC braille specifications are...
-
11B-206.2.8 Employee work areas
Large pieces of equipment, such as electric turbines or water pumping apparatus, may have stairs and elevated walkways used for overseeing or monitoring purposes which are physically part...
-
Maintenance of Accessible Features
The regulations recognize that it is not sufficient to provide features such as elevators, toilet rooms and assistive listening systems if those features are not maintained in a manner that...
-
General [4.1.6(1)]
achieving level slopes at accessible parking where work involves resurfacing but not regrading limitations imposed by existing walls that are not being moved or altered, elevator...