Where the exit discharge does not include an accessible route from an exit located on a level of exit discharge to a public way, an exterior area of assisted rescue shall be provided on...
Search Results "Golf Car Rental Area"
-
1007.7.1 Level of exit discharge
-
68.101(c)(5)(A) Accessible parking
(A) If parking is required as part of the lease agreement or is provided to serve the leased area, accessible parking spaces shall comply with TAS 208 and 502....
-
10. Drinking fountains and water coolers
Accessible element or space ANSI A117.1 section APPLICATION 10. Drinking fountains and water coolers 4.15 Fifty percent of...
-
Accessible Routes: ADA Standard Section 1002.2
In load or unload areas and on amusement rides, where compliance with 405.2 is not structurally or operationally feasible, ramp slope shall be permitted to be 1:8 maximum. 2....
-
PROVIDING ACCESSIBLE POLLING PLACES
In this rare circumstance, election administrators may provide “curbside voting” to allow persons with disabilities to vote outside the polling place or in their cars. ...
-
1007.4 Elevators
The elevator shall be accessed from either an area of refuge complying with Section 1007.6 or a horizontal exit....
-
11B-1002.2 Accessible routes
Exceptions: In load or unload areas and on amusement rides, where compliance with Section 11B-405.2 is not structurally or operationally feasible, ramp slope shall be permitted...
-
11B-1002.2 Accessible routes
Exceptions: In load or unload areas and on amusement rides, where compliance with Section 11B-405.2 is not structurally or operationally feasible, ramp slope shall be permitted...
- GameTime Merry-Go-All Play Component
-
408.3.2.2 Duration
Power-operated swinging doors shall remain open for 20 seconds minimum when activated.
-
11B-408.3.2.1 Power operation
Swinging doors shall be power-operated and shall comply with ANSI/BHMA A156.19.
-
11B-408.3.2.2 Duration
Power-operated swinging doors shall remain open for 20 seconds minimum when activated.
-
408.3.2.1 Power Operation
Swinging doors shall be power-operated and shall comply with ANSI/BHMA A156.19 (1997 or 2002 edition) (incorporated by reference, see "Referenced Standards" in Chapter 1).
-
e-vii
e-vii. Is the elevator equipped with audible tones or bells or verbal annunciators that announce each floor as it is passed? [ADA Standards § 4.10.13] Yes No
-
e-v
e-v. Are raised letters and Braille characters used to identify each floor button and each control? [ADA Standards § 4.10.12] Yes No
-
§ 36.304(b)(18)
(18) Creating designated accessible parking spaces;
-
§ 36.304(b)(6)
(6) Adding raised markings on elevator control buttons;
-
Sec.36.304(b)(6)
(6) Adding raised markings on elevator control buttons;
-
Sec.36.304(b)(18)
(18) Creating designated accessible parking spaces;
-
5f.
5f. Is the elevator equipped with audible tones or bells or verbal annunciators that announce each floor as it is passed? [ADA Stds 4.10.13]
-
A4.10.6 Door Protective and Reopening Device
The required door reopening device would hold the door open for 20 seconds if the doorway remains obstructed. After 20 seconds, the door may begin to close. However, if designed in...
-
A4.10.6 DOOR PROTECTIVE AND REOPENING DEVICE
The required door reopening device would hold the door open for 20 seconds if the doorway remains unobstructed. After 20 seconds, the door may begin to close. However, if designed in...
-
F208 Parking Spaces
[See subsections ...]
-
Must the minimum number of spaces be determined separately for each parking facility on a site or can it be based on the collective total of spaces provided on a site?
The minimum number of accessible parking spaces, including van accessible spaces, must be calculated separately for each parking facility on a site. Spaces required for one parking...