The front partition and at least one side partition shall provide a toe clearance of 9 inches (230 mm) minimum above the finish floor and 6 inches (150 mm) deep minimum beyond the compartment-side...
Search Results "Side Transfer"
-
604.8.1.4 Toe Clearance
-
Mounting Location and Height [4.30.6]
Mounting Location and Height [4.30.6] Placement of tactile signs aside doors (latch-side) provides safety since locating signs on doors that swing out is hazardous....
-
11B-608.5.3 Alternate roll-in type shower compartments
In alternate roll-in type shower compartments, operable parts of controls and faucets shall be installed on the side wall of the compartment adjacent to the seat wall 19 inches (483 mm)...
-
11B-608.5.3 Alternate roll-in type shower compartments
In alternate roll-in type shower compartments, operable parts of controls and faucets shall be installed on the side wall of the compartment adjacent to the seat wall 19 inches (483 mm)...
-
Clear Ground Space [1011.2]
Fire rings, grills, fireplaces, and woodstoves 48 by 48 inches on all usable sides of a fire ring, grill, fireplace, and woodstove....
-
Ramps M303:3.3, 3.3.1, 3.3.2
Ramps with drop offs ½ inch or greater would be required to provide edge protection 2 inches high minimum on each side to prevent users from inadvertently travelling off the sides of the...
-
308 Reach Ranges
In the final rule, the maximum side reach has been lowered to the height specified for forward reaches....
-
11B-809.10.7.1 Floor space
The floor space at water closets shall be 48 inches (1219 mm) wide minimum measured perpendicular to the side wall....
-
11B-809.10.7.1 Floor space
The floor space at water closets shall be 48 inches (1219 mm) wide minimum measured perpendicular to the side wall....
- Trench Drain SSB 5038TR .75 Base
-
R409.2 Where Required
Handrails shall be provided on both sides of ramps and stairways....
-
Clarification on Standard Roll-In Shower Compliance
with a full opening width on the long side."...
-
Section 5 References
Section 5 References i http://udeworld.com/analysis-of-seat-height-for-wheeled-mobility-devices ii ”The Impact of Transfer Setup on the Performance of Independent Transfers: Final...
-
Conclusion
Center Study at the University of Buffalo, New York: The Wheeled Mobility Anthropometry Project, Final Report, page 49, Figure 3-5, reference to “All Device Types*”. 3 “The Impact of Transfer...
-
Water Play Components: ADA Standard Section 1008.2.3
Transfer systems complying with 1008.3 shall be permitted to connect elevated play components in water. Advisory 1008.2.3 Water Play Components....
- Zurn Insulation Combination Kit: One Trap Protector, Two Stop Supply Protectors and One Offset Drain Protector
-
Where must curb ramps be provided?
Curb ramps must be located to ensure a person with a mobility disability can travel from a sidewalk on one side of the street, over or through any curbs or traffic islands, to the sidewalk...
-
Cross Slope [1017.7.2]
Cross slope is the side-to-side slope of a trail tread....
-
1. & 2. Sidewalk Slope
.: slopes tilting side to side) less than 1:50 (critical dimension of ´" or less) [sic] so persons who use wheelchairs can conveniently negotiate the routes?...
-
[F] WORKSTATION
Examples include ticket booths; the employee side of grocery store check stands; the bartender area behind a bar; the employee side of snack bars, sales counters and public counters; guardhouses...
-
4.34.6.8* REFRIGERATOR/FREEZER
Provision shall be made for refrigerators which are: (1) Of the vertical side-by-side refrigerator/freezer type; or (2) Of the over-and-under type and meet the following requirements...
-
[F] WORKSTATION
Examples include ticket booths; the employee side of grocery store check stands; the bartender area behind a bar; the employee side of snack bars, sales counters and public counters; guardhouses...
-
[F] WORKSTATION
Examples include ticket booths; the employee side of grocery store check stands; the bartender area behind a bar; the employee side of snack bars, sales counters and public counters; guardhouses...
-
11B-705.1.2.2.1 Perpendicular curb ramps
Detectable warnings shall extend the full width of the ramp run less 2 inches (51 mm) maximum on each side, excluding any flared sides....