One side of the wheelchair space shall adjoin an accessible route when in the load and unload position....
Search Results "Patient Seated in Wheelchair"
-
11B-1002.4.6 Approach
-
11B-1002.4.6 Approach
One side of the wheelchair space shall adjoin an accessible route when in the load and unload position....
-
1002.4.6 Approach
One side of the wheelchair space shall adjoin an accessible route when in the load and unload position....
-
11B-607.2 Clearance
Where a permanent seat is provided at the head end of the bathtub, the clearance shall extend 12 inches (305 mm) minimum beyond the wall at the head end of the bathtub....
-
General: ADA Standard Section 226.1
Section 226.1 of the ADA Standards covers information in the current ADA Standards on scoping requirements for dining surfaces and work surfaces.
-
1002.4.6 Approach
One side of the wheelchair space shall adjoin an accessible route when in the load and unload position....
-
11B-608.3.3 Alternate roll-in type shower compartments
Grab bars shall not be provided above the seat. Grab bars shall be installed 6 inches (152 mm) maximum from adjacent walls....
-
608.3.3 Alternate Roll-In Type Shower Compartments
Grab bars shall not be provided above the seat. Grab bars shall be installed 6 inches (150 mm) maximum from adjacent walls....
-
M301.4.1 Clearance in Base
[See subsections ...]
-
Access to Performing Areas [4.33.5]
Access to Performing Areas [4.33.5] An accessible route must connect wheelchair spaces with performing areas, including stages, arena floors, playing fields, dressing and locker rooms...
-
604.8.1.4 Toe Clearance
Figure 604.8.1.4 Wheelchair Accessible Toilet Compartment Toe Clearance...
-
ยง 38.107(a)
(a) If a restroom is provided for the general public, it shall be designed so as to allow a person using a wheelchair or mobility aid to enter and use such restroom as specified in paragraphs...
-
608.3.3 Alternate Roll-In Type Shower Compartments
Grab bars shall not be provided above the seat. Grab bars shall be installed 6 inches (150 mm) maximum from adjacent walls....
-
11B-608.3.3 Alternate roll-in type shower compartments
Grab bars shall not be provided above the seat. Grab bars shall be installed 6 inches (152 mm) maximum from adjacent walls....
-
607.2 Clearance
Where a permanent seat is provided at the head end of the bathtub, the clearance shall extend 12 inches (305 mm) minimum beyond the wall at the head end of the bathtub....
-
604.8.1.4 Toe Clearance
[ECTCR UFAS 4.17.4] Figure 604.8.1.4 Wheelchair Accessible Toilet Compartment Toe Clearance...
-
604.8.1.4 Toe Clearance
Figure 604.8.1.4 Wheelchair Accessible Toilet Compartment Toe Clearance...
-
Advance Notice Only for Particular Services and Equipment
on an aircraft with fewer than 60 seats; Provision by the carrier of hazardous materials packaging for the battery of a wheelchair or other assistive device; Accommodations...
-
11B-608.3.3 Alternate roll-in type shower compartments
Grab bars shall not be provided above the seat. Grab bars shall be installed 6 inches (152 mm) maximum from adjacent walls....
-
Clear Floor Space
Clear Floor Space The load and unload areas adjacent to ride seats designed for transfer must have a clear space of 30 by 48 inches minimum....
-
604.8 Toilet Compartments
Wheelchair accessible toilet compartments shall meet the requirements of 604.8.1 and 604.8.3. Compartments containing more than one plumbing fixture shall comply with 603....
-
604.8 Toilet Compartments
Wheelchair accessible toilet compartments shall meet the requirements of 604.8.1 and 604.8.3. Compartments containing more than one plumbing fixture shall comply with 603....
-
608.3.3 Alternate Roll-In Type Shower Compartments
Grab bars shall not be provided above the seat. Grab bars shall be installed 6 inches (150 mm) maximum from adjacent walls....
-
607.2 Clearance
Where a permanent seat is provided at the head end of the bathtub, the clearance shall extend 12 inches (305 mm) minimum beyond the wall at the head end of the bathtub....