Floor or ground surface within required maneuvering clearances shall comply with 302. Changes in level are not permitted. EXCEPTIONS: 1. Slopes not steeper than 1:48 shall be...
Search Results "Door Operator"
-
404.2.4.4 Floor or Ground Surface
-
10.4.1(5)
(5) Baggage check-in and retrieval systems shall be on an accessible route complying with 4.3, and shall have space immediately adjacent complying with 4.2.4. If unattended security...
-
4.1.6(3)(d)(i)
(i) Where it is technically infeasible to comply with clear opening width requirements of 4.13.5, a projection of 5/8 in maximum will be permitted for the latch side stop.
-
11B-404.2.4.4 Floor or ground surface
Floor or ground surface within required maneuvering clearances shall comply with Section 11B-302. Changes in level are not permitted. Exceptions: 1. Slopes not steeper than...
- Panda S.15 All Wood with Aluminum Core Lift & Slide System
- Panda S.11 Aluminum/Wood Clad Lift & Slide System
-
Plan 4B: 13-Foot Wide Accessible Guest Room
Features include an alternate roll-in shower with a seat, comparable vanity, wardrobe, and door connecting to adjacent guest room. Furnishings include two beds. Â ...
-
Plan 3B: 12-Foot Wide Accessible Guest Room
Features include a standard roll-in shower with a seat, comparable vanity, wardrobe, and door connecting to adjacent guest room. Furnishings include two beds. Â ...
-
Plan 2A: 13-Foot Wide Accessible Guest Room
Features include a standard roll-in shower with a seat, comparable vanity, wardrobe, and door connecting to adjacent guest room....
- Cavity Sliders USA Inc. Wall Mount Track
- Panda IS.14 Aluminum Wood Clad IMPACT Lift & Slide System
-
A. Accessible Voting Program
For all facilities not owned by Harris County, Harris County shall maintain in operable working condition on Election Day those features of facilities and equipment owned by Harris County...
- DORMA T900 Series Locks
- Don-Jo Mfg., Inc. Door Flip Guards 1603
- Don-Jo Mfg., Inc. Door Flip Guards 1604
- Stanley Access Technologies Dura-Care 7200 Manual Sliding Door
- Cavity Sliders USA Inc. FH Ceiling Mount Track
- Panda IS.14 All Aluminum IMPACT Lift & Slide System
- Sargent AD8600 & NB-AD8600 Concealed Vertical Rod Exit Device for Aluminum Doors
-
3) Where the standard says "Changes in level are not permitted", but no advisory follows the standard
3) Where the standard says "Changes in level are not permitted", but no advisory follows the standard, such as 404.2.4.4 floor or ground surfaces at doors: Although the Advisory at 304.2...
-
LaCantina Aluminum Wood Slider System Flush Sill
Requires the Premium User plan or above. (Login or upgrade your account!)