From NBC Nightly News, Thursday, June 14, 2007, reported by Roger O'Neil: News story about a Pro golfer, Jim Estes, who is helping wounded war veterans. Estes is providing free golf...
Search Results "Construction Support Facility"
- What Works on NBC: Giving the Gift of Golf to Wounded Warriors
-
F238.2.1 Teeing Grounds
Where one teeing ground is provided for a hole, the teeing ground shall be designed and constructed so that a golf car can enter and exit the teeing ground....
-
11B-238.2.1 Teeing grounds
Where one teeing ground is provided for a hole, the teeing ground shall be designed and constructed so that a golf car can enter and exit the teeing ground....
-
11B-238.2.1 Teeing grounds
Where one teeing ground is provided for a hole, the teeing ground shall be designed and constructed so that a golf car can enter and exit the teeing ground....
-
11B-238.2.1 Teeing grounds
Where one teeing ground is provided for a hole, the teeing ground shall be designed and constructed so that a golf car can enter and exit the teeing ground....
-
238.2.1 Teeing Grounds
Where one teeing ground is provided for a hole, the teeing ground shall be designed and constructed so that a golf car can enter and exit the teeing ground....
-
Safe Harbor is applied element by element in existing facilities
1) An existing place of public accommodation (facility) has an element type that was constructed and/or last altered before 3/15/2012 and that fully complies with the 1991 ADA Standard. ...
-
TECHNICALLY INFEASIBLE
[DSA-AC] An alteration of a building or a facility, that has little likelihood of being accomplished because the existing structural conditions require the removal or alteration of a load-bearing...
-
11B-206.7.10 Recreational boating facilities and fishing piers and platforms
Platform lifts shall be permitted to be used instead of gangways that are part of accessible routes serving recreational boating facilities and fishing piers and platforms....
-
11B-206.7.10 Recreational boating facilities and fishing piers and platforms
Platform lifts shall be permitted to be used instead of gangways that are part of accessible routes serving recreational boating facilities and fishing piers and platforms....
-
11B-206.7.10 Recreational boating facilities and fishing piers and platforms
Platform lifts shall be permitted to be used instead of gangways that are part of accessible routes serving recreational boating facilities and fishing piers and platforms....
-
I fully support ADA requirements and the DGS' efforts. We are reconstructing a 325 space parking lot. 8% will be EVSE ready. 32 EVSE will be installed initially. Including EVSE required ADA spaces, new plan results in 322 spaces. Parking facility no longer complies with minimum parking requirements for facilities. Any suggestions for resolving this conflict for reworking of existing sites subject to CALGreen?
RESPONSE: Parking ordinances are typically adopted within each city and county in California and enforced by local planning department personnel. You could consider requesting a...
-
Must the minimum number of spaces be determined separately for each parking facility on a site or can it be based on the collective total of spaces provided on a site?
The minimum number of accessible parking spaces, including van accessible spaces, must be calculated separately for each parking facility on a site....
-
11B-703.1.1 Plan review and inspection
Signs as specified in Section 11B-703, or in other sections of this code, when included in the construction of new buildings or facilities, or when included, altered or replaced due to additions...
-
11B-703.1.1 Plan review and inspection
Signs as specified in Section 11B-703, or in other sections of this code, when included in the construction of new buildings or facilities, or when included, altered or replaced due to additions...
-
1011.6 Water Spouts
Water spouts at water hydrants and water utility hook-ups shall be 28 inches (710 mm) minimum and 36 inches (915 mm) maximum above the ground.
-
1011.6 Water Spouts
Water spouts at water hydrants and water utility hook-ups shall be 28 inches (710 mm) minimum and 36 inches (915 mm) maximum above the ground.
-
1.1.10 Ramps
1.1.10 Ramps. Measure accessible ramps for overall running slope and cross slope as well as local running slope and cross slope variations (flatness) in accordance with Sections...
-
1.1.14 Flatness of ramp cross slope
1.1.14 Flatness of ramp cross slope. For ramps, measure flatness of cross slope by placing a 24 - in. (600 mm) digital inclinometer perpendicular to the line of travel at 4 ft (1200...
-
1.1.16 Alternate measurement tools
1.1.16 Alternate measurement tools. Ramps may be measured with instruments other than a digital inclinometer if they provide the data required for evaluation of tolerances as given...
-
1.1.6 Flatness of walk cross slope
1.1.6 Flatness of walk cross slope. For walks and other pedestrian paths, measure flatness of the cross slope by placing a 24 - in. (600 mm) digital inclinometer perpendicular to the...
-
238.2.1 Teeing Grounds
Where one teeing ground is provided for a hole, the teeing ground shall be designed and constructed so that a golf car can enter and exit the teeing ground....
-
Private Businesses that Serve the Public: Public Accommodations
If you own, operate, lease, or lease to a business that serves the public, then, you are covered by the ADA and have obligations for existing facilities as well as for compliance when a...
