They noted that premium seats may have to be removed and that load-bearing walls may have to be relocated....
Search Results "Back Wall"
-
Location of accessible routes to stages. (Section-by-Section Analysis)
- Kawneer North America 260/360/560 Insulclad™ Thermal Entrances
- Bobrick ClassicSeries Recessed Seat-Cover Dispenser B-301
- Symmetry Vertical Platform Lift VPC-SL
- Landscape Forms Inc. Sonoma Bench Collection
- Pilot Rock RT Series End Accessible Recycled Plastic Picnic Table
- Cybex Total Access Leg Extension Exercise Machine
-
After January 26, 1992
Examples of changes in usability include: changing a low pile carpet to a thick pile carpet, moving walls, installing new toilets, or adding more parking spaces to a parking lot....
-
Fixed Seating and Tables
Fixed Seating and Tables If tables are provided, such as in restaurants and snack bars, and the tables are attached to the wall or floor (fixed), then 5% of the tables or at least one...
-
809.2.5 Bedrooms in Emergency Transportable Housing Units
The section also requires a means to control at least one source of lighting from the bed, such as bedside lamps, wall switches near the bed, or remote control devices that can be operated...
-
11B-805 Medical care and long-term care facilities
inches (203 mm) minimum increasing to 29 inches (737 mm) high minimum above the finish floor or ground at the front edge of a counter with a built-in lavatory or at the front edge of a wall-mounted...
-
CASI Accessibility Construction Inspection Checklist
During construction inspection finish product thicknesses such as flooring materials or wall coverings must be considered when reviewing critical accessibility features, including but not...
-
CALBO Accessibility Construction Inspection Checklist
During construction inspection finish product thicknesses such as flooring materials or wall coverings must be considered when reviewing critical accessibility features, including but not...
-
Types of Alternative Designs
Swing-away grab bars were typically located on both sides of the toilet rather than fixed grab bars on the side and rear walls as indicated in ADAAG....
-
Water Closet Clearance
The 1991 Standards allow the nearest side of a lavatory to be placed 18 inches minimum from the water closet centerline and 36 inches minimum from the side wall adjacent to the water closet...
-
Tiles
The agency’s third playground with TIL was bordered by a landscaped paver retaining wall. ...
-
Wheelchair Spaces
Where a main circulation path is located behind a seating row with a wheelchair space that is entered from the back, the aisle in front of the row may need be to be wider in order not to...
-
How to Measure Transfer Surface Height
centerlines of the seat, and the height from the floor to the highest point of the transfer surface: The depth is measured between the perineal cutout and the hinge point at the back...
-
Perpendicular Curb Ramps (R304.2) (Section-by-Section Analysis)
Where the turning space is constrained at the back of the sidewalk, the turning space must be 1.2 meters (4 feet) minimum by 1.5 meters (5 feet) minimum, with the 1.5 meters (5 feet) dimension...
-
Standards for Individual Captioning Devices (Section-by-Section Analysis)
If a movie theater adopts an all-reserved seating policy, it would be advisable to hold back certain seats for individuals who need captioning (or audio description) if the captioning (or...
-
How: Tips on Completing Emergency Health Information
When completing your emergency health information (forms included at back of this guide) be sure and include: Disability/Conditions affecting emergency care (if you are not sure, list...
-
Checklist for Inclusive Emergency Safety Briefings for Attendees
Avoid directions that are not inclusive, such as: look for the closest exit, exit through the green door in the back of...
-
3.3.2 Unoccupied Device Length
Third, many of today’s mobility users attach accessories to the back of their device; we included the accessories in our length measurements....
-
Other Contrast Attributes
Later, I came back – the chairs were gone. So I asked – I went back to the director and I said, what happened? Oh, Jesus, somebody made a mistake and delivered the wrong chairs....