(iii) Costs associated with providing accessible telephones, such as relocating the telephone to an accessible height, installing amplification devices, or installing a text telephone (TTY...
Search Results "Adjustable Height Counter"
-
§ 36.403(f)(2)(iii)
-
§ 35.151(b)(4)(iii)(B)(3)
(3) Costs associated with providing accessible telephones, such as relocating a telephone to an accessible height, installing amplification devices, or installing a text telephone (TTY);...
-
703.5.7 Stroke Thickness
Stroke thickness of the uppercase letter "I" shall be 10 percent minimum and 30 percent maximum of the height of the character....
-
§ 36.403(f)(2)(iii)
(iii) Costs associated with providing accessible telephones, such as relocating the telephone to an accessible height, installing amplification devices, or installing a text telephone (TTY...
-
M303.2.4.1 Toe Clearance
Toe clearance shall be provided at a height of 9 inches (230 mm) above the floor to a depth of 6 inches (150 mm) maximum....
-
§ 35.151(b)(4)(iii)(B)(3)
(3) Costs associated with providing accessible telephones, such as relocating the telephone to an accessible height, installing amplification devices, or installing a text telephone (TTY...
-
Toilet Compartments: ADA Standard Section 213.3.1
Section 213.3.1 covers scoping requirements in the current ADA Standards for toilet compartments.
-
11B-407.2.1.3 Clear floor or ground space
The height of the clear floor or ground space is considered to be a volume from the floor to 80 inches (2030 mm) above the floor....
-
11B-407.2.1.3 Clear floor or ground space
The height of the clear floor or ground space is considered to be a volume from the floor to 80 inches (2030 mm) above the floor....
- Just Manufacturing Classroom Concealed Ledgemount Single Handle Restricted Swing Faucet
- Just Manufacturing Deck Mounted Classroom Faucet with Vandal Resistant Lever Handle
-
Appendix Two: Design Information and Accommodation Models
Research findings on Occupied Height Type of WhMD user Sam-ple Size Mean (SD) Min 5%ile 10%ile Me-dian 90%ile 95%ile Max...
-
§382.133(e)(2)
(2) The maximum weight and dimensions (length, width, height) of the device to be used by an individual that can be accommodated in the aircraft cabin consistent with FAA safety requirements...
-
4.34.5.2(2)
(2) The height of the water closet shall be at least 15 in (380 mm), and no more than 19 in (485 mm), measured to the top of the toilet seat....
-
308 Reach Ranges
In the final rule, the maximum side reach has been lowered to the height specified for forward reaches....
-
Base Support [No specific provision—affects M303.2.4]
To discuss the maximum base support height, the sub-committee looked at anthropomorphic data regarding footrest heights....
- Westside Center for Independent Living - Los Angeles, Santa Monica, CA
-
Obstacles [1018.5]
When beach access routes are constructed of concrete, asphalt, or boards, obstacles cannot exceed one-half inch in height at their highest point....
-
Data Deficiencies
Data Deficiencies Advocates on the committee, representing the interests of people with disabilities, strongly stated that a 17” height is essential to accommodate the largest segment...
-
11B-705.1.1.1 Dome size
warning surface shall have a base diameter of 0.9 inch (22.9 mm) minimum and 0.92 inch (23.4 mm) maximum, a top diameter of 0.45 inch (11.4 mm) minimum and 0.47 inch (11.9 mm) maximum, and a height...
-
Standards for Individual Captioning Devices (Section-by-Section Analysis)
These commenters wanted the Department to ensure that the text that is exhibited on these devices is readable with good contrast and good text size, that it be available at a reasonable height...
-
M301.3.1 Transfer Supports
The support could be made to be both height adjustable and detachable at floor level....
-
Obstacles [1016.5]
The limit on the height of obstacles on ORARs, passing spaces, and resting intervals is based on the surface material used....
-
Data Analysis
Descriptive statistics were used to find the population-based percentile level, highest, and lowest heights for transfers for the one-step transfer protocols A, B, and C and the two-step...