Exterior landings of impervious construction (e.g., concrete, brick, flagstone) serving primary entry doors and required exit doors are limited to not more than ½ inch (12.7 mm) of change...
Search Results "Curb Ramp Top Landing"
Commonly Searched Documents
-
1132A.4, Item 1
-
[A] PUBLIC WAY
A street, alley or other parcel of land open to the outside air leading to a street, that has been deeded, dedicated or otherwise permanently appropriated to the public for public use and...
-
505.10.3 Bottom Extension at Stairs
Extension shall return to a wall, guard, or the landing surface, or shall be continuous to the handrail of an adjacent stair flight. ...
-
1132A.4, Item 1
Exterior landings of impervious construction (e.g., concrete, brick, flagstone) serving primary entry doors and required exit doors are limited to not more than ½ inch (12.7 mm) of change...
-
5.8.2.8 Knee and Toe Clearance Recommendations Summary
For such a measurement, the top of the breast platform will be moved to 34 inches above the ground, and then the clearance dimensions will be measured just as they would be on any stationary...
-
11B-1009.2.4 Seat
The height of the lift seat shall be designed to allow a stop at 17 inches (432 mm) minimum to 19 inches (483 mm) maximum measured from the deck to the top of the seat surface when in the...
-
11B-1009.2.4 Seat
The height of the lift seat shall be designed to allow a stop at 17 inches (432 mm) minimum to 19 inches (483 mm) maximum measured from the deck to the top of the seat surface when in the...
-
11B-610.3 Shower compartment seats
The top of the seat shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum above the bathroom finish floor....
-
902.3 Height
The tops of dining surfaces and work surfaces shall be 28 inches (710 mm) minimum and 34 inches (865 mm) maximum above the finish floor or ground....
-
11B-410.8 Restriction sign
A sign complying with Section 11B-703.5 _|Signs; Visual Characters|_ shall be posted in a conspicuous place at each landing and within the platform enclosure stating “No Freight” and include...
-
11B-410.8 Restriction sign
A sign complying with Section 11B-703.5 _|Signs; Visual Characters|_ shall be posted in a conspicuous place at each landing and within the platform enclosure stating “No Freight” and include...
-
USE ZONE
immediately adjacent to a play structure or play equipment that is designated by ASTM F 1487 for unrestricted circulation around the play equipment and where it is predicted that a user would land...
-
Public Way
Any street, alley or other parcel of land open to the outside air leading to a public street, which has been deeded, dedicated or otherwise permanently appropriated to the public for public...
-
12207(a) Study
--The National Council on Disability shall conduct a study and report on the effect that wilderness designations and wilderness land management practices have on the ability of individuals...
-
106.5.51 Public Way
Any street, alley or other parcel of land open to the outside air leading to a public street, which has been deeded, dedicated or otherwise permanently appropriated to the public for public...
-
12207(a) Study
(a) Study The National Council on Disability shall conduct a study and report on the effect that wilderness designations and wilderness land management practices have on the ability of...
-
Q2.) What are the types of “field conditions” that were anticipated where the advisory says “tolerances recognized by this provision include those for field conditions”?
And a concrete finisher clearly cannot guarantee that the slope of a concrete curb ramp will be consistently 8.33% across its entire surface. ...
-
Unobstructed: ADA Standard Section 308.3.1
Section 308.3.1 covers the current ADA Standards for unobstructed side reach.
- Adaptive Access
-
604.9.3 Height
The height of water closets shall be 11 inches (280 mm) minimum and 17 inches (430 mm) maximum measured to the top of the seat....
-
604.9.3 Height
The height of water closets shall be 11 inches (280 mm) minimum and 17 inches (430 mm) maximum measured to the top of the seat....
-
11B-604.9.3 Height
The height of water closets shall be 11 inches (279 mm) minimum and 17 inches (432 mm) maximum measured to the top of the seat....
-
1008.3.1.2 Height
The height of transfer platforms shall be 11 inches (280 mm) minimum and 18 inches (455 mm) maximum measured to the top of the surface from the ground or floor surface....
-
Handrail Extensions [§505.10]
Handrail Extensions [§505.10] Handrail extensions at the top and bottom must return to walls, guards, or floors and horizontal portions must comply as protruding objects....