Note: in some circumstances such as in-room MR, the option for a room layout for gurney transfer would be appropriate....
Search Results "Diagnostic Room"
-
M301.4 Lift Compatibility
-
M101.2 Application
As discussed above under Organization of Technical Criteria, the technical criteria are to be applied to medical diagnostic equipment based on the following patient positions that the equipment...
-
Attachment I
Court Room in City Hall There are no wheelchair seating locations for the public in the Court Room. ...
-
Positioning Supports Considered
patients in a supine, prone or side-lying position, and diagnostic equipment used by patients in a seated position that can be adjusted to a reclined position....
-
Objective of, and legal basis for, the proposed standards
The objective of the proposed standards is to ensure that medical diagnostic equipment is accessible to and usable by individuals with disabilities....
-
viii. Hospital beds and gurneys
Medical care and long-term care facilities do not always provide accessible beds in the patient and resident sleeping rooms required to be accessible....
-
M302.3.2 Leg Supports (Section-by-Section Analysis)
The MDE NPRM did not propose to require stirrups to provide a method of supporting, positioning, and securing the patient’s legs for diagnostic equipment used by patients in the seated position...
-
4.3.2 Transfer Surfaces and Imaging Equipment Functions
These procedures are only performed after screening mammography and/or diagnostic mammography (or another diagnostic imaging assessment) has been performed....
-
G.5.ii. - How is the "back office" exception applied?
Hardware that might meet these dual conditions includes: telephone equipment placed on racks in a "closet" or small room and network routers and storage devices or servers located in rooms...
-
a. Transfer Surface Adjustability
The MDE NPRM proposed that the same transfer surface height range of 17 inches minimum to 19 inches maximum be applied to both diagnostic equipment used in the supine, prone, or side-lying...
-
Overhead Lifts
The technical criteria do not address overhead lifts that are usually mounted on the ceiling and operate on tracks suspended over the diagnostic equipment because the configuration of the...
-
M301.2.1 Transfer Surface Height
Additionally these magnetic fields also preclude use of a patient’s mobility device in the exam room....
-
I. Introduction
Introduction This Minority Report has been developed by the following medical diagnostic imaging equipment industry members of the Advisory Committee to the U.S....
-
Height
The Access Board is considering whether 6 inches minimum and 19 inches maximum above the transfer surface would be an appropriate height for transfer supports on diagnostic equipment used...
-
ADOPTION OF A 19 INCH HEIGHT MINIMIZES COSTS TO HEALTH CARE PROVIDERS
We (representing medical table and chair manufacturers) estimated the costs of various examination table heights under consideration by the Medical Diagnostic Equipment Technical Advisory...
-
12. Q: If an older child has delayed speech or developmental disabilities, can we place that child in the infant or toddler room?
Q: If an older child has delayed speech or developmental disabilities, can we place that child in the infant or toddler room? A: Generally, no....
-
Question 1
The Department is considering adopting the Access Board's standards for medical diagnostic equipment....
-
Question 2
The Access Board is expected to promulgate design standards for medical and dental diagnostic tables and chairs....
-
M302.3.1 Transfer Supports (Section-by-Section Analysis)
In the MDE NPRM the Access Board proposed that transfer supports must be provided for use with transfer sides on diagnostic equipment used by patients in the seated position, and that these...
-
Clear floor space at Lav
Terry, You should identify the minimum dimensions of the clear floor space at the Lav.
-
Transfer Surface Size: Equipment Used by Patients in a Seated Position (M302.2.2)
Seats on diagnostic equipment used by patients in a seated position typically provide back and arm support for patient comfort and stability....
-
2.1 General
ORARs shall be provided between units and constructed features in campgrounds, picnic areas, trailheads, viewing areas, and other outdoor recreation sites. ORARs shall connect...
-
M301.4.1 Clearance in Base (Section-by-Section Analysis)
that the patient could be raised out of their mobility device, moved over to the medical diagnostic equipment, and then be lowered onto the transfer surface....