B-279 ClassicSeries® Surface-Mounted Waste Receptacle Satin-finish stainless steel. Bottom edges hemmed for safety....
Search Results "Walking Surface"
Commonly Searched Documents
- Bobrick B-279 ClassicSeries® Surface-Mounted Waste Receptacle
- Bobrick TrimLineSeries ADA Surface-Mounted Hand Dryer B-7128.115V
-
11B-705.2 Detectable directional texture
transit boarding platforms shall comply with Figure 11B-705.2 and shall be 0.1 inch (2.5 mm) in height that tapers off to 0.04 inch (1.0 mm) , with bars raised 0.2 inch (5.1 mm) from the surface...
-
Gratings [4.5.4]
These requirements apply to gratings located in any walking surface, including courtyards and plazas, not just those on accessible routes....
-
11B-705.2 Detectable directional texture
transit boarding platforms shall comply with Figure 11B-705.2 and shall be 0.1 inch (2.5 mm) in height that tapers off to 0.04 inch (1.0 mm) , with bars raised 0.2 inch (5.1 mm) from the surface...
-
1.1.8 Alternate measurement tools
Walks may be measured with instruments other than a digital inclinometer if they provide the data required for evaluation of tolerances as given in Sections 1.2.1, 1.2.2, and 1.2.3....
-
1018.2 Aisles in assembly spaces
required for applications listed in Section 1.9.1 regulated by the Division of the State Architect-Access Compliance, shall also comply with Chapter 11A or Chapter 11B, Section 11B-403 _|Walking...
-
4.32 SEATING, TABLES, AND WORK SURFACES
[See subsections ...]
-
A4.32 SEATING, TABLES, AND WORK SURFACES
[See subsections ...]
-
11B-809.9.7 Exposed pipes and surfaces
Exposed water supply and drain pipes under sinks and lavatories shall comply with Section 11B-606.5.
- Bobrick TrimLineSeries ADA Surface-Mounted Hand Dryer B-7128.230V
- American Safety Tread Co., Inc. Cast Metal Safety Stair Nosing Style 801
-
Detectable Warning Surfaces on Boarding Platforms Used by Buses and Rail Vehicles, and Boarding and Alighting Areas Used by Rail Vehicles (Section-by-Section Analysis)
Detectable Warning Surfaces on Boarding Platforms Used by Buses and Rail Vehicles, and Boarding and Alighting Areas Used by Rail Vehicles (Section-by-Section Analysis) The 1991 ADAAG...
-
403.5.1 Clear Width
Except as provided in 403.5.2 and 403.5.3, the clear width of walking surfaces shall be 36 inches (915 mm) minimum....
- CRL PR40 Series Adjustable Spring Power Surface Mounted Door Closers
-
29. Please indicate what the length of time was between the installation of the trail surface material and the first necessary repair
Please indicate what the length of time was between the installation of the trail surface material and the first necessary repair: 1 month 3 months 6 months...
-
Jean Tessmer
I have used this tool for concrete, asphalt, and raised board walk construction work on federal and private commercial projects....
-
Standardized Tests of Physical Fitness and Community Ambulation
Subjects were also asked to rate the difficulty they had walking or wheeling on the ADAAG course....
-
403.5.3 Passing Spaces
Passing spaces shall be either: a space 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum; or, an intersection of two walking surfaces providing a T-shaped space complying with...
-
403.5.1 Clear Width
Except as provided in 403.5.2 and 403.5.3, the clear width of walking surfaces shall be 36 inches (915 mm) minimum....
- Boost Your Business - Chapter 2 - Parking
- Sloan Optima® EHD-401 Sensor Activated Hand Dryer for Surface Mounting
-
A4.4.1 GENERAL
Visually impaired people walking toward an object can detect an overhang if its lowest surface is not higher than 27 in (685 mm)....