This assumes a rate of about 1.5 ft/s (455 mm/s) on level ground. It also assumes that the traveler would move continuously....
Search Results "Teeing Ground"
-
A4.3.1(1) Travel Distances
-
4.6.3* PARKING SPACES
EXCEPTION: If accessible parking spaces for vans designed for handicapped persons are provided, each should have an adjacent access aisle at least 96 in (2440 mm) wide complying with 4.5, Ground...
-
III-8.1000 General
The ADA establishes two avenues for enforcement of the requirements of title III -- 1) Private suits by individuals who are being subjected to discrimination or who have reasonable grounds...
-
Elevators
Result: People with disabilities who are unable to use stairs and steps cannot gain access to floors above and below the ground level and, in many instances, do not have access to the...
-
Stairs
At the top, the extension shall be parallel with the floor or ground surface....
-
1009.7.2 Separation
The fire-resistance-rated construction shall extend vertically from the ground to a point 10 feet (3048 mm) above the floor level of the area for assisted rescue or to the roof line, whichever...
-
11B-704.2.1.2 Forward approach
Where a forward approach is provided at a telephone within an enclosure, the counter may extend beyond the face of the telephone 20 inches (508 mm) into the required clear floor or ground...
-
11B-805 Medical care and long-term care facilities
306.3.3, Exception 1 which states: "At lavatories required to be accessible by Section 11B-213.3.4, the knee clearance shall be 27 inches (686 mm) high minimum above the finish floor or ground...
-
Tent Pads and Tent Platforms
Provide a minimum 48-inch (1,220-millimeter) clear floor or ground space on all sides of tents on tent pads and platforms that are required to be accessible....
-
Preserving elevator access in building where it might not be required.
Landlord asks: if it's a restaurant and all of the features offered on the mezz area are offered on the ground floor (206.2.5), can he render the mezz inaccessible, that is, not provide...
- Pilot Rock ART Series End Accessible Recycled Plastic Picnic Table With Arched Frame
- Endorphin 325 Functional Wall Pulley
-
Elevator Exemption (Preamble, Section-by-Section Analysis)
Generally, an elevator is the most common way to provide individuals who use wheelchairs ‘‘ready access’’ to floor levels above or below the ground floor of a multi-story building....
-
Elevator Exemption (Section-By-Section Analysis and Response to Comments)
Generally, an elevator is the most common way to provide individuals who use wheelchairs "ready access'' to floor levels above or below the ground floor of a multi-story building....
-
Can parking signage height be considered a "safe harbor"?
Signs designating parking places for disabled people can be seen from a driver’s seat if the signs are mounted high enough above the ground and located at the front of a parking space....
-
11B-704.2.1.2 Forward approach
Where a forward approach is provided at a telephone within an enclosure, the counter may extend beyond the face of the telephone 20 inches (508 mm) into the required clear floor or ground...
-
1007.7.4 Separation
The fire-resistance-rated construction shall extend vertically from the ground to a point 10 feet (3048 mm) above the floor level of the area for assisted rescue or to the roof line, whichever...
-
307.2 Protrusion Limits
Objects with leading edges more than 27 inches (685 mm) and not more than 80 inches (2030 mm) above the finish floor or ground shall protrude 4 inches (100 mm) maximum horizontally into...
-
4.4.1* GENERAL
Free-standing objects mounted on posts or pylons may overhang 12 in (305 mm) maximum from 27 in to 80 in (685 mm to 2030 mm) above the ground or finished floor (see Fig. 8(c) and (d))....
-
Hand Cycles (Stand-Alone)
The caster wheels do not touch the ground unless the rider leans the bicycle to one side or the other....
-
Door and Gate Surfaces [§404.2.10]
These requirements do not apply to: Sliding doors Doors and gates that do not extend to within 10” of the finish floor or ground Existing doors or gates with kick...
-
Error/Omission: Adequate maneuvering clearance is not provided at doors, including doors to accessible toilet stalls.
The floor or ground area within the required clearances shall be level and clear. 4.17.5* Doors. Toilet stall doors, including door hardware, shall comply with 4.13....
-
§ 38.83(b)(2)(i) Requirements
., ground, curb, and intermediate positions) normally encountered in the operating environment....