Abrupt Level Changes - Are hallways and corridors free of any steps or abrupt vertical level changes over 1/4" that will impede access for persons who use wheelchairs, walkers, and other...
Search Results "Vertical Standing Support"
Commonly Searched Documents
-
A. Changes in Level
-
608.6 Shower Spray Unit and Water
If an adjustable-height shower head on a vertical bar is used, the bar shall be installed so as not to obstruct the use of grab bars....
-
2.1.2.1 Summary of IEC 118‒4 (1981) Standards
These values apply to the vertical component of the field strength inside the area enclosed by the loop, measured 1.2 meters above the floor....
-
Station 6-Speed
Design speed is critical in determining horizontal and vertical alignments. Speed is also used in calculating necessary sight distances....
-
608.6 Shower Spray Unit and Water
If an adjustable-height shower head on a vertical bar is used, the bar shall be installed so as not to obstruct the use of grab bars....
-
11B-703.7.2.6.3 Unisex toilet and bathing facilities
The vertices of the triangle symbol shall be located 1/4 inch (6.4 mm) maximum from the edge of the circle symbol with a vertex pointing upward....
-
11B-703.7.2.6 Toilet and bathing facilities geometric symbols
Where a door is provided the symbol shall be mounted within 1 inch (25 mm) of the vertical centerline of the door....
-
1009.7.2 Separation
The fire-resistance-rated construction shall extend vertically from the ground to a point 10 feet (3048 mm) above the floor level of the area for assisted rescue or to the roof line, whichever...
- Landscape Forms Inc. Multiplicity Bench Collection
-
4. Exception from the Requirements of M301 for Certain Examination Chairs that Comply with M302
The Access Board proposed in M101.2 in the MDE NPRM to require diagnostic equipment to meet the standards for each patient position supported, meaning that if diagnostic equipment was designed...
-
11B-221.6 Semi-ambulant seats
(i) It is located within the rear 60% of the seats provided in an auditorium; or (ii) It is located within the area of an auditorium in which the vertical...
-
11B-221.6 Semi-ambulant seats
(i) It is located within the rear 60% of the seats provided in an auditorium; or (ii) It is located within the area of an auditorium in which the vertical...
-
11B-221.6 Semi-ambulant seats
following criteria — i) It is located within the rear 60% of the seats provided in an auditorium; or i) It is located within the area of an auditorium in which the vertical...
-
Birthing Room Bath Tub Accessibility
I was surprised to find that the highlighted selection supports the Owner's desire not to provide a seat or grab bars to the bathtub in a birthing room that has an accessible shower....
- Kawneer North America 1010C Sliding Mall Front
- Grohe Grandera Two-Handle Bidet Mixer 1/2" M-Size Faucet
- Inpro Corporation JointMaster® 925 Fire Barrier System Expansion Joint Systems
- Gamco Surface-Mounted Robe Hook Satin - 76717
-
DSA IR 16-12: GRAB BAR DESIGN AND CONNECTIONS: 2019 CBC
The wall capacity shall be established in the same manner. 2.3 As an alternate to Section 2.2 above for grab bars spanning 36” or less between supports, a connection using a back-up...
-
Covered Content on Primary Web Sites
Commenters who supported flexibility and carrier choice also expressed the view that fewer compliance options would inhibit carrier innovation and use of new technologies, limit Web site...
-
Maintenance of Accessible Features
An entity should recognize that certain types of equipment may require more staff support and maintenance than others (e.g. ensuring there are enough batteries for a pool lift to maintain...
-
5.2.1 Transfer Surface Size Recommendations for M301
The technical criteria do not address the overall width and depth of patient support surfaces because of the diverse shape and size of these surfaces....
-
If the manufacturer states that the design load is 800 pounds, can the transportation operator limit actual use to 600 pounds for safety reasons?
The manufacturer’s design load represents the amount of weight that the lift is capable of supporting....
-
504.2 Content Creation or Editing (Section-by-Section Analysis)
section proposes to require authoring tools to include at least one mode of operation for creating or editing content that conforms to WCAG 2.0 Success Criteria for all features and formats supported...