The 1991 Standards contain no exception for grab bar length, and require the water closet centerline to be exactly 18 inches from the side wall, while the 2010 Standards requirement allows...
Search Results "Side Reach"
-
Water Closet Location and Rear Grab Bar
-
Temporary Solutions For Emergency Sheltering - Protruding Object Hazards
Temporary Solutions For Emergency Sheltering - Protruding Object Hazards Problem: Objects protrude too far from the side into the route causing a hazard for people who are blind or who...
-
Example of a Single-User Bathroom (with Roll-in Shower)
Where clear floor space at a lavatory is obstructed on both sides more than 2 feet, a clearance at least 36 inches wide is required....
-
Hand Cycles (Stand-Alone)
Additional support, as required, is provided by small caster wheels that are mounted on each side just behind the seat....
-
Error/Omission: Adequate maneuvering clearance is not provided at doors, including doors to accessible toilet stalls.
If toilet stall approach is from the latch side of the stall door, clearance between the door side of the stall and any obstruction may be reduced to a minimum of 42 in (1065 mm) (Fig. 30...
-
610.3 Shower Compartment Seats
Where a seat is provided in a standard roll-in shower compartment, it shall be a folding type, shall be installed on the side wall adjacent to the controls, and shall extend from the back...
-
GUARD OR GUARDRAIL
A building component or a system of building components located at or near the open sides of elevated walking surfaces that minimizes the possibility of a fall from the walking surface to...
-
11B-409.3 Elevator doors
Exception: Doors shall not be required to comply with the maneuvering clearance requirements in Section 11B-404.2.4.1 for approaches to the push side of swinging doors....
-
4.21.5 Controls
In shower stalls 36 in by 36 in (915 mm by 915 mm), all controls, faucets, and the shower unit shall be mounted on the side wall opposite the seat....
-
4.21.5 CONTROLS
In shower stalls 36 in by 36 in (915 mm by 915 mm), all controls, faucets, and the shower unit shall be mounted on the side wall opposite the seat....
-
4.7.11 ISLANDS
Any raised islands in crossings shall be cut through level with the street or have curb ramps at both sides and a level area at least 48 in (1220 mm) long in the part of the island intersected...
-
11B-409.3 Elevator doors
Exception: Doors shall not be required to comply with the maneuvering clearance requirements in Section 11B-404.2.4.1 for approaches to the push side of swinging doors....
-
1009.7.3 Openness
The sides other than the separation walls shall be not less than 50 percent open, and the open area shall be distributed so as to minimize the accumulation of smoke or toxic gases....
-
1009.7.3 Openness
The sides other than the separation walls shall be not less than 50 percent open, and the open area shall be distributed so as to minimize the accumulation of smoke or toxic gases....
-
11B-409.3 Elevator doors
Exception: Doors shall not be required to comply with the maneuvering clearance requirements in Section 11B-404.2.4.1 for approaches to the push side of swinging doors....
-
11B-607.5 Controls
Controls shall be between the bathtub rim and grab bar, and between the open side of the bathtub and the centerline of the width of the bathtub....
- Pilot Rock BS Series Bike Stand
-
1007.7.5 Openness
The sides other than the separation walls shall be at least 50 percent open, and the open area shall be distributed so as to minimize the accumulation of smoke or toxic gases....
-
1134A.6, Item 1.3
configurations shall measure at least 36 inches deep by 60 inches wide (914 mm by 1524 mm) with an entrance opening of at least 36 inches (914 mm) when a wall is installed on the opening side...
-
Is clear floor space required to be centered on elements?
standards require the clear floor space to be centered on wheelchair accessible drinking fountains (forward approach), kitchen work surfaces, (forward approach), and washers and dryers (side...
-
1134A.6, Item 1.3
configurations shall measure at least 36 inches deep by 60 inches wide (914 mm by 1524 mm) with an entrance opening of at least 36 inches (914 mm) when a wall is installed on the opening side...
-
§ 37.131(a)(1)(iv)
(iv) For purposes of this paragraph, the core service area is that area in which corridors with a width of three-fourths of a mile on each side of each fixed route merge together such that...
-
§ 38.93(a)(1)
(1) At least one door on each side of the car from which passengers board opening onto station platforms and at least one adjacent doorway into the passenger coach compartment, if provided...