3. Swinging doors shall be capable of opening at least 90 degrees.
Search Results "Residential Facility"
Commonly Searched Documents
-
1132A.3, Item 3
-
1132A.3, Item 5
5. A pair of doors, manual or automatic, must have at least one leaf which provides a clear width of not less than 32 inches (813 mm), measured with the door positioned at an angle...
-
1132A.3, Item 2
2. Swinging doors shall provide a net clear opening width of not less than 32 inches (813 mm), measured with the door or doors positioned at an angle of 90 degrees from the closed...
-
11B-809.8.1 Door Thresholds
Secondary exterior door thresholds, including sliding door tracks, shall be 3/4 inch (19.1 mm) high maximum with a 1:2 maximum slope.
-
11B-809.10.6.2 Slope
The slope of the shower floor shall be 1/2 inch (12.7 mm) per foot maximum in any direction and shall slope to a drain. The floor surfaces shall be of Carborundum, grit-faced tile or...
-
11B-809.10.7 Water closets
Water closets required by Section 11B-809.10 shall comply with this section.
-
11B-809.10 Toilet and bathing rooms
[See subsections ...]
-
11B-809.10.5.2 Reinforcement for grab bars
Reinforcement for grabs bars shall comply with the following: 1. Where bathtubs are installed without surrounding walls reinforcement shall be provided for floor-mounted grab...
-
11B-809.7 Accessible routes
An accessible route shall be provided complying with Section 11B-809.7. The accessible route shall pass through the primary entry door, through all rooms within the dwelling unit and...
-
11B-809.10.6.6 Controls
Controls and operating mechanisms shall comply with Section 11B-309.4.
-
11B-809.10.6.7 Shower enclosures
Doors and panels of shower enclosures shall comply with Section 11B-809.10.5.4.
-
11B-206.4.4.1 Location
In transportation facilities, where different entrances serve different transportation fixed routes or groups of fixed routes, entrances serving each fixed route or group of fixed routes...
-
M. NEW CONSTRUCTION, ALTERATIONS, AND PHYSICAL CHANGES TO FACILITIES
Altered Facilities: The County will take the actions listed in Attachment H to make the altered parts of the County facilities for which alterations commenced after January 26, 1992, readily...
-
F206.7 Platform Lifts
Platform lifts shall be permitted as a component of an accessible route in an existing building or facility. [ECTCR UFAS 4.1.2(5) 2nd Exception]...
-
11B-805 Medical care and long-term care facilities
SECTIONS 11B-805 Medical care and long-term care facilities 11B-805.2 Patient bedrooms and resident sleeping rooms....
-
11B-216.13 Variable message signs
Where provided in transportation facilities, variable message signs conveying transportation-related information shall comply with Section 11B-703.8....
- The GRIT Freedom Chair
-
11B-216.14 Variable message signs
Where provided in transportation facilities, variable message signs conveying transportation-related information shall comply with Section 11B-703.8....
-
608.4 Seats (Exception)
An exception to the section permits seats to not be installed in transfer type shower compartments in residential dwelling units required to provide mobility features provided that the walls...
-
11B-216.13 Variable message signs
Where provided in transportation facilities, variable message signs conveying transportation-related information shall comply with Section 11B-703.8....
-
Section 37.43 Alteration of Transportation Facilities by Public Entities
of an existing facility....
-
§ 35.150 Existing facilities.
[56 FR 35716, July 26, 1991, as amended by Order No. 1694-93, 58 FR 17521, Apr. 5, 1993; AG Order No. 3180-2010, 75 FR 56180, Sept. 15, 2010; AG Order 3332-2012, 77 FR 30179, May 21,...
-
Section 37.9 Standards for Transportation Facilities
37, which incorporates the Access Board facility guidelines....
-
11B-232.2.1.4 Technically infeasible
Where it is technically infeasible to locate a substitute cell within the same prison site in compliance with Section 11B-232.2.1.3, a substitute cell shall be provided at another...