Length Clear floor space complying with TAS 305 for a forward approach is required for an accessible dining surface based on TAS 902.2....
Search Results "Clear Width at Turn"
-
Technical Memorandum TM 2013-14 Dining Surfaces
-
Can handrail extensions wrap or turn?
Handrail extensions must be in the same direction as the stair flight, but continuous handrails can wrap at the inside turn of switchback or dogleg stairways....
-
Attachment H: Modifications to Altered Facilities
Attachment H: Modifications to Altered Facilities
-
1132A.3 Width and height of interior doors and secondary exterior doors
Swinging doors shall provide a net clear opening width of not less than 32 inches (813 mm), measured with the door or doors positioned at an angle of 90 degrees from the closed position....
-
11B-802.1.2 Width
Advisory 11B-802.1.2 Width. Figure 11B-802.1.2 (b) depicts paired wheelchair spaces requiring a total of 66 inches in width....
- Wikk Industries Inc. PART#BPS SM-INGR CLEAR (628) with I36-3 CLEAR (628)
- American Standard Right Width 1.28-1.6 gpf FloWise Right Height Elongated Flushometer Toilet
-
11B-802.1.2 Width
Advisory 11B-802.1.2 Width. Figure 11B-802.1.2 (b) depicts paired wheelchair spaces requiring a total of 66 inches in width....
-
Conclusion
When transferring to the platform, a 104 inch wide by 55.5 inch deep clear floor space in front of the platform accommodated 100% of the study participants when considering all types of...
-
11B-407.3.6 Width
The width of elevator doors shall comply with Table 11B-407.4.1. Exception: In existing elevators, a power-operated car door complying with Section 11B-404.2.3 shall be permitted....
-
11B-407.3.6 Width
The width of elevator doors shall comply with Table 11B-407.4.1. Exception: In existing elevators, a power-operated car door complying with Section 11B-404.2.3 shall be permitted....
-
11B-407.3.6 Width
The width of elevator doors shall comply with Table 11B-407.4.1. Exception: In existing elevators, a power-operated car door complying with Section 11B-404.2.3 shall be permitted....
-
Priority 2: Access to Goods & Services
Word Fillable Form (2.5MB) Word Non-Fillable Form (2.4MB) PDF Non-Fillable Form (1.4MB)
-
General description of monetized benefits for water closet clearance in single-user toilet rooms—out-swinging doors (Req. #28)
In order to assess monetized benefits for the requirement covering water closet clearances in single-user toilet rooms with out-swinging doors, a determination needed to be made...
-
General description of monetized benefits for water closet clearance in single-user toilet rooms—out-swinging doors (Req. # 28)
In order to assess monetized benefits for the requirement covering water closet clearances in single-user toilet rooms with out-swinging doors, a determination needed to be made...
-
Side Entry: ADA Standard Section 1002.4.4.2
The amount of clear space needed within the ride, and the size and position of the opening are interrelated....
-
11B-1002.4.4.2 Side entry
The amount of clear space needed within the ride, and the size and position of the opening are interrelated....
-
11B-1002.4.4.2 Side entry
The amount of clear space needed within the ride, and the size and position of the opening are interrelated....
-
3.3.1 Unoccupied Device Width
3.3.1 Unoccupied Device Width The unoccupied widths of devices were similar for the mean and 80th percentile values across research findings from different countries (Figure 3‒1)....
-
D6. Vestibule Clear Floor Space
If an entry has a vestibule, is there a 30-inch by 48-inch clear floor space inside the vestibule where a wheelchair or scooter user can be outside the swing of a hinged door?...
-
Can handrail extensions wrap or turn?