At least one sleeping area shall provide a clear floor space complying with 305 on both sides of a bed....
Search Results "Wheelchair Passing Space"
Commonly Searched Documents
-
Sleeping Areas: ADA Standard Section 806.2.3
-
What kinds of securement equipment must be provided in buses and vans?
Section 38.23(d) of the DOT ADA regulations requires all ADA-compliant buses and vans to have a two-part securement system, one to secure the wheelchair, and a seat belt and shoulder...
-
What kinds of securement equipment must be provided in buses and vans?
Section 38.23(d) of the DOT ADA regulations requires all ADA-compliant buses and vans to have a two-part securement system, one to secure the wheelchair, and a seat belt and shoulder harness...
-
On existing locations when we add an EV station as van accessible how do we address taking two spaces from the facility (losing a space) and then not having the mandatory spaces remaining for the facility?
RESPONSE: All work is required to comply with the applicable codes, standards and ordinances. Parking ordinances are typically adopted within each city and county in California....
-
1012.1 General
This section contains the technical requirements for parking spaces provided within camping units and picnic units with mobility features and pull-up spaces for recreational vehicles at...
-
Note
Note: In every instance, regardless of toilet and lavatory configuration, adequate space needs to be provided for inmates who use wheelchairs to transfer onto and off of the toilet....
-
C. Air Travelers with a Disability Changing Planes
Where needed and to the extent required by law, you must provide services personnel, wheelchairs, and ramps or mechanical lifts....
-
1016.8.4 Turning Space
Where resting intervals are provided adjacent to an outdoor recreation access route, a turning space complying with 304.3.2 shall be provided. ...
-
1016.8.4 Turning Space
Where resting intervals are provided adjacent to an outdoor recreation access route, a turning space complying with 304.3.2 shall be provided....
-
UFAS vs. ADAAG Comparison
Elevator req'd to serve each level in all multi-story bldgs. by UFAS but not for certain private entity bldgs. under ADAAG. 4.1.2(18)a Number of req'd wheelchair...
-
C. Boarding and Deplaning Assistance
[Sec. 382.39(a)] The type of assistance you must offer includes, as needed, services personnel and the use of wheelchairs, ramps, or mechanical lifts....
-
5.1.3 Slope
The slope of the surface of the clear floor or ground space inside the camp shelter shall not be steeper than 1:48 (2 percent) in all directions....
- Eclipse Partitions Stall Breakdown Animation
- Hadrian Powder Coated Headrail Braced Toilet Partition Installation
-
5.3.5 Doors
The door shall not swing into or otherwise obstruct the clear floor or ground space required by 5.3.2.1. ...
-
Section 36.308 Seating in Assembly Areas (Section-by-Section Analysis)
This provision would have required assembly areas with more than 5,000 seats to provide five wheelchair spaces with at least three designated companion seats for each of those five wheelchair...
-
1007.3.1 Start of Play
A clear floor or ground space 48 inches (1220 mm) minimum by 60 inches (1525 mm) minimum with slopes not steeper than 1:48 shall be provided at the start of play....
-
1007.3.1 Start of Play
A clear floor or ground space 48 inches (1220 mm) minimum by 60 inches (1525 mm) minimum with slopes not steeper than 1:48 shall be provided at the start of play....
-
11B-1007.3.1 Start of play
A clear floor or ground space 48 inches (1219 mm) minimum by 60 inches (1524 mm) minimum with slopes not steeper than 1:48 shall be provided at the start of play....
-
11B-1007.3.1 Start of play
A clear floor or ground space 48 inches (1219 mm) minimum by 60 inches (1524 mm) minimum with slopes not steeper than 1:48 shall be provided at the start of play....
-
11B-1007.3.1 Start of play
A clear floor or ground space 48 inches (1219 mm) minimum by 60 inches (1524 mm) minimum with slopes not steeper than 1:48 shall be provided at the start of play....
-
1007.3.1 Start of Play
A clear floor or ground space 48 inches (1220 mm) minimum by 60 inches (1525 mm) minimum with slopes not steeper than 1:48 shall be provided at the start of play....
-
J2
If the drinking fountain is a floor-mounted unit, is there clear floor space at least 30 inches long x 48 inches wide (60 inches if it is in an alcove) for a side approach to the drinking...
-
806 Transient Lodging Guest Rooms
Substantive changes made to this section revise requirements for: vanity counter spaces in accessible toilet or bathing rooms (806.2.4.1) wheelchair turning space (806.2.6...