This would mean that the wing wall could not extend beyond the front edge of a lavatory located on the other side of the wall from the water closet....
Search Results "Side Reach"
-
31.1 Q. Can a water closet (toilet) be located in an alcove with a wing wall?
-
604.6 Flush Controls
Flush controls shall be located on the open side of the water closet except in ambulatory accessible compartments complying with 604.8.2....
-
11B-804.2.2 U-Shaped
In U-shaped kitchens enclosed on three contiguous sides, clearance between all opposing base cabinets, counter tops, appliances, or walls within kitchen work areas shall be 60 inches (1524...
-
409.3 Elevator Doors
EXCEPTION: Doors shall not be required to comply with the maneuvering clearance requirements in 404.2.4.1 for approaches to the push side of swinging doors....
-
804.2.2 U-Shaped
In U-shaped kitchens enclosed on three contiguous sides, clearance between all opposing base cabinets, counter tops, appliances, or walls within kitchen work areas shall be 60 inches (1525...
-
607.5 Controls
Controls shall be between the bathtub rim and grab bar, and between the open side of the bathtub and the centerline of the width of the bathtub. Controls shall comply with 309.4....
-
Re: Lavatories Adjacent to Partitions
11B-606.6 Adjacent side wall or partition. Lavatories, when located adjacent to a side wall or partition, shall be a minimum of 18 inches (457 mm) to the centerline of the fixture....
-
205 Operable Parts
securement devices (Exception 7) exercise machines (Exception 8) The proposed rule contained an exception from the technical requirement that operable parts be within accessible reach...
-
Transfer Entry
Transfer Entry There is a large amount of variance in amusement rides and the sides of the ride are often part of the restraint or securement system....
-
K4
, drink, condiment, and tableware dispensers are provided, are dispensers and operating controls mounted no higher than 54 inches above the floor if clear floor space is provided for a side...
-
Jamb Signage
...are all elevator jambs provided with signs placed on both sides designating the floor with 2" minimum height raised letters and Braille characters centered at 60" above the finish floor...
-
4.17.4 Toe Clearances
In standard stalls, the front partition and at least one side partition shall provide a toe clearance of at least 9 in (230 mm) above the floor....
-
5e.
Are signs mounted on both sides of the elevator hoistway door opening that designate the floor with 2-inch minimum-height raised letters and Braille characters centered at 60 inches above...
-
Assembly Areas
where they adjoin seating and since accessible routes are required to connect to wheelchair seating locations, compliance with 4.9, including requirements for handrails, is not required at sides...
-
4.17.4 TOE CLEARANCES
In standard stalls, the front partition and at least one side partition shall provide a toe clearance of at least 9 in (230 mm) above the floor....
-
4.34.5.5(4) Controls
In the shower stall in Fig. 35(a), all controls, faucets, and the shower unit shall be mounted on the side wall opposite the seat....
-
228 Depositories, Vending Machines, Change Machines, and Mail Boxes
Gas pump manufacturers expressed concerns about reach range requirements and operating force specifications which have been addressed in the final rule, as discussed in sections 308 and...
-
Transfer Height
If multiple transfers are necessary to reach the amusement ride seat, it is recommended that each vertical transfer not exceed 8 inches....
-
B. PRELIMINARY ISSUES
Before reaching the question of whether Kirola has Article III standing, the Court addresses four preliminary contentions concerning the constellation of evidence which may be considered...
-
c-ii
If No, then either provide back-up electrical power to operate the lift or elevator during the power outage or locate shelter services exclusively on accessible levels that may be reached...
-
2.3.1 Standards
When the NYS standards were drafted in l988‒89, the manufacturers could not reach a consensus regarding minimum energy level of the IR light at a set distance from the emitters....
-
Aisle Seats
The proposed rule required that such seats have removable or folding armrests or no armrests on the aisle side....
-
1007.7.4 Separation
The fire-resistance-rated exterior wall construction shall extend horizontally 10 feet (3048 mm) beyond the landing on either side of the landing or equivalent fire-resistance-rated construction...